HOME > FIELDPIECE > CLAMP-METERS > SC67 fieldpiece logo

Fieldpiece SC67
Manual Ranging Clamp Meter
with Temperature Range up to 1000ºF
See: SC620

Click here for a larger image of the Fieldpiece SC67 Manual Ranging Clamp Meter with TemperatureClick here for a larger image
Fieldpiece SC67 Shown
Product Information
Datasheet 667 KB PDF Datasheet
Manual 493 KB PDF Datasheet
SC67 Movie
PDF HelpPDF Help
  • MicroAmps DC for Flame Diodes
  • Non-Contact Voltage
  • High Voltage Alert
  • Volts AC
  • Volts DC
  • Resistance (Ohms)
  • Diode Test
  • Rugged ABS case
  • Ergonomic shape fits naturally in your hand
  • Auto power-off (APO) to conserve battery life

IF Multiple Accessory head instruments seem too cumbersome, but still want a great meter for HVAC/R, the Fieldpiece SC67 Manual Ranging Clamp Meter with Temperature Range up to 1000ºF is a great choice. The Fieldpiece SC-67 is a manual ranging clamp on meter that includes most of the electrical ranges you use for HVAC/R plus temperature, up to 1000 degrees Fahrenheit with a compatible k-type thermocouple, for a great price. The Fieldpiece SC 67 also has several safety features like a high-voltage LED and beeper, a continuity warning, push button non-contact voltage (NCV), a lead holder on the clamp, and MAX hold so you can concentrate on the test point, hook up, and see the results after you’ve disconnected. The Fieldpiece SC67 also includes capacitance (MFD) for checking motor-start and motor-run capacitors and microamps DC for flame diode tests. Techs agree that the Fieldpiece SC67 Manual Ranging Clamp Meter is a solid performer for everyday HVAC/R testing.

A lot of guys in the field just want a simple, easy to use, and convient meter; A meter designed for the way that they work. The Fieldpiece SC67 has ranges high enough for most HVAC/R field tests at a great price. Because it's a Fieldpiece, The SC67 Manual Ranging Clamp Meter is rugged, feels solid and naturally fits in your hand.


Designed specifically for HVAC/R field service, the Fieldpiece SC67 Manual Ranging Clamp Meter with Temperature is a dedicated DMM and offers specific features and benefits to HVAC/R field service pros including:

Non-contact Voltage
With the NCV tab on the tip of the clamp close to an AC voltage, press and hold the NCV button. The NCV LED will light with an analog feel and the beeper will beep. The closer you get to AC voltage, the louder the beep. The NCV function is sensitive enough to detect 24VAC on thermostats (24V to 600V, 50Hz to 60Hz).

High Voltage and Continuity Indicators
If the user is using the Fieldpiece SC66 while doing lab testing, these features would probably drive you crazy. Fieldpiece took input from more than one HVAC/R veteran in order to make sure that these features really remind the user of what they're doing and they’ve avoided potentially dangerous situations in the field. The Hi-V LED and beeper let you know when you’ve hooked up to a circuit over 30V. The continuity LED and beeper tells the user if a circuit is open or closed.

Using the built-in amp clamp, the user can use the Fieldpiece SC 67 to read 0-200 amps directly on your meter with 0.1 resolution.

Capacitance (MFD)
With the Fieldpiece SC67, users can measure microfarads on motor-run and motor-start capacitors using the Capacitance range. To use, first disconnect the capacitor from power first, then Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation.


Take ambient air or refrigeration line temperatures and more with the built-in K-type port and the included the Fieldpiece ATB1 wrap tab thermocouple. Add a wet sock (saturated tissue or a shoelace to take wet bulb temperatures. The built-in temperature junction offers great temperature compensation for more accurate and faster measurements.

Microamps DC - Flame Rectification Tests
The most common "no heat" call has to do with a malfunctioning flame sensing diode. Simply turn the Fieldpiece SC67 Clamp Meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly.

Fieldpiece ADK7 attached lead clip on the to help you perform a one-hand test more easily than most meters

Silicone Leads
Because the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. Use the attached lead clip on the to help the user perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job. Fieldpiece's Deluxe Silicone Lead Kit, model ADK7, is an optional purchase from your favorite distributor and makes one-handed testing even easier.

Wire Grabbing Jaw
The Fieldpiece SC 67's fixed jaw is longer than the moveable jaw to make it easier to select just one wire from a bundle. With the jaws closed, separate one wire using the long fixed jaw then slide it to the corner where the two jaws meet; Finally, open the jaws to let it in. Now you can select the wire without holding the jaws open.

MAX Hold
The MAX hold button is easily pressed while holding the mini clamp meter naturally in your hand. The Fieldpiece SC67 holds the maximum reading when hooking up to a test point. The Fieldpiece SC66 Dual Display Mini Clamp Meter for HVAC/R is a safer way to test, so you can concentrate on the test points and look at the LCD after you’ve disconnected.

Fieldpiece SC67 Dial Settings/Ranges
Selecting Ranges
For DC voltage, set the meter to the VDC parameter instead of VAC as shown below. For all ranges and functions choose a range just above the value you expect. If display reads "OL" (overload), select a higher range. If display shows less than three numbers, select a lower range for better resolution.
Function Range Accuracy
Display Counts 2000 n/a
AC Volts (2,3) 200 1.2% + 3 / 0.1
600 2% + 5 / 1
AC Amps 200 3% + 5 / 0.1 (1)
DC Volts (2) 200 0.5% + 1 / 0.1
DC Amps (Series)(4) 200µ 1% + 1 / 0.1
Resistance (Ohms)(9) 200 1%+3 / 0.1
200K 1% + 3 / 0.1k
Microfarads (6) 200 3% + 5 / 0.1
Temperature (°F) (5) 200 1°F / 0.1
1000 1% + 1.5°F / 1
Continuity Check (10) Yes
Diode Test Yes
Diode Test (7) Yes
Probe Storage Yes
NCV (8) Yes
MAX Hold (11) Yes
Amp OL Protection PTC

(1) - 50-60Hz
(2) - Input impedance is 560Kohms on volts ranges, 10Mohm on millivolts ranges. All ranges will withstand 600VAC/600VDC
(3) - 50Hz-500Hz
(4) - Protected by PTC (positive temperature coefficient) resistor. If an overload occurs on microamps DC, disconnect from circuit for 30 seconds so the PTC can reset
(5) - Accuracy 1OF (32OF to 120OF); 1%+1.5OF (-4OF to 750OF); 2%+4OF (-30OF to -4OF, 750OF to 1000OF); all withstand 30V max
(6) - Test frequency 34Hz at >3.5V. Will withstand up to 500V
(7) - Turns on <30V
(8) - Senses 24VAC to 600VAC
(9) - 0.3VDC typical open circuit voltage.(3V on 200ohm range). Withstands up to 500V on any ohms range
(10) - Turns on >100 ohms within 100mS. Will withstand up to 500V
(11) - Holds highest reading
Technical Specifications
Field °F calibration
For accuracies of ±°F, calibrate the Fieldpiece HS35 to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used.
Fieldpiece SC45 calibration
  1. Select the 200°F range.
  2. Remove back case and hold the battery in place with a rubber band so terminals are touching
  3. Stabilize a large cup of ice water
  4. Immerse the thermocouple probe and let it stabilize
  5. Adjust VR3 (below battery) to get close to 32°F (0°C) then adjust VR3 (right of battery) to get within 0.1°F (0.1°C) of 32.0°F (0.0°C)
  6. To calibrate in °C, close the jumper that is just below VR3
Indicators Low battery. Overrange: "OL" is displayed.
Environmental Operating temperature 32°F to 122°F
Storage: 0°F to 140°F with batteries removed, RH >80%.
Measurement rate 2.5 times/sec nominal
Battery 9V NEDA 1604; 150 hours typical with carbon zinc (installed).
Auto power off Meter automatically turns off after approximately 1 hour.
Temperature coefficient 0.1 X (specified accuracy) per °F above 82°F and below 64°F
Industry specifications IEC/ EN61010-1, IEC/EN61010-2-32, Cat III (600V for SC66 and SC67) class 2 and pollution degree 2, in accordance with IEC-664 indoor use. UL listed to UL3111. C-Tick certified.
Ordering Information
Model Description Buy Online Price
SC67  Fieldpiece SC67 Manual Ranging Clamp Meter with Temperature Range up to 1000° Discontinued
See: SC620
Included Accessories
  • 1 - Wrap Tab K-Type Thermocouple (ATB1)
  • 1 - Silicone Test Leads (ASLS2)
  • 1 - Large Single Meter Case (ANC7)
  • 1 - 9-Volt battery (installed)
  • 1 - Operator's manual
Optional Accessories
ANC1 Fieldpiece ANC1 4 pocket Deluxe Meter Case Buy Now Sale $12.80
(Reg. $16.00)
ANC3 Fieldpiece ANC3 Large Briefcase-Style Instrument Bag Buy Now Sale $60.00
(Reg. $75.00)
ANC5 Fieldpiece ANC5 Mail Pouch-Style Meter Case Buy Now Sale $8.00
(Reg. $10.00)
ANC7 Fieldpiece ANC7 Large Single Meter Case Buy Now Sale $7.20
(Reg. $9.00)
ANC8 Fieldpiece ANC8 Large Deluxe Meter Case Buy Now Sale $26.40
(Reg. $33.00)
ANC9 Fieldpiece ANC9 Wireless Refrigerant Scale Case Buy Now Sale $16.00
(Reg. $20.00)