HOME > FIELDPIECE > CLAMP-METERS > SC45 fieldpiece logo

Fieldpiece SC45
Mini Clamp Meter with Temperature for HVAC/R
See: SC220

Click here for a larger image of the Fieldpiece SC45 Mini Clamp Meter with Temperature for HVAC/RClick here for a larger image
Fieldpiece SC45 Shown
Product Information
Datasheet 261 KB PDF Datasheet
Manual 645 KB PDF Datasheet
PDF HelpPDF Help
  • Non-contact Voltage
  • AC Volts
  • DC Volts
  • Resistance (Ohms)
  • Continuity
  • Temperature
  • Capacitance
  • Autoranging
  • Rugged ABS case
  • Ergonomic shape fits naturally in your hand
  • Auto power-off (APO) to conserve battery life
  • Under 8" tall

The Fieldpiece SC45 Mini Clamp Meter with Temperature for HVAC/R, incorporates a lot of big meter functions into a compact, easy to hold and use design. While it’s not exactly an all-in-one multimeter, the Fieldpiece SC 45 manual and auto ranging DMM includes most of the ranges used in HVAC/R everyday. Along with standard multimeter ranges, Fieldpiece designed the SC45 to include capacitance (MFD) and temperature with great compensation. Additonally, Fieldpiece designed the SC-45 with built-in non-contact voltage and a continuity beeper to give the user a powerful HVAC/R meter that’s under 8-inches tall. The Fieldpiece SC 45 is a great backup or a solid performer for everyday testing.

The Fieldpiece SC45 Mini Clamp Meter with Temperature for HVAC/R has features and benefits of many full-size meters in a design that is only 8-inches tall. The built-in non-contact voltage sensor (NCV) sensor tells the user if a line is hot or not before they work on it. The continuity beeper tells the user if a circuit is open or closed. The Fieldpiece SC45 also features the hold button on the side of the SC45, which allows the user to concentrate on the test point, hold the reading and then look at the display after the Fieldpiece SC-45 is disconnected.


Features and Benefits

Like all of our test instruments, the main benefit of the Fieldpiece SC-45 is that it was designed specifically for HVAC/R field service. The Fieldpiece SC45 Mini Clamp Meter with Temperature for HVAC/R is rugged, has with built-in safety features and includes most of the ranges the user needs for everyday testing. Some of the highlights include:

Take ambient air or refrigeration line temperatures and more with the built-in K-type port and the included ATB1 wrap tab thermocouple. Add a wet sock, saturated tissue, or a shoelace to take wet bulb temperatures. The built-in temperature junction offers great temperature compensation for more accurate and faster measurements.

Using the attached amp clamp of the Fieldpiece SC45, read 0-400 amps directly on your meter with 0.1 resolution.

Wire Grabbing Jaw
The amp clamp is shaped like a jaw to make grabbing a single wire easy using only one hand.

Non-contact Voltage
With the NCV tab on the tip of the clamp close to an AC voltage, press and hold the NCV button pn the Fieldpiece SC45. The NCV LED will light with an analog feel and the beeper will beep. The closer the user gets to AC voltage, the louder the beep will be on the Fieldpiece SC 45. The NCV function is sensitive enough to detect 24VAC on thermostats (24V to 600V, 50Hz to 60Hz).

The HOLD button is easily pressed with the thumb while holding the mini clamp meter naturally in the user's hand. The Fieldpiece SC-45 holds any reading so the user can concentrate on the test points and look at the LCD after being disconnected.

Fieldpiece SC45 Dial Settings/Ranges

The Fieldpiece SC45 Mini Clamp Meter's dial is easy to operate with one hand. Fieldpiece SC45's compact design allows you to select the range the user's need using one finger or thumb and get the job done fast.

Selecting Ranges
For DC voltage, set the Fieldpiece SC44 Mini Clamp Meter for HVAC/R to the VDC parameter instead of VAC. For all ranges, the user will choose a range just above the value you expect. If display reads "OL" (overload), select a higher range. If display shows less than three numbers, select a lower range for better resolution.

AC Volts (50Hz - 500Hz)
Ranges: 4V, 40V, 400V, 600V
Resolution: 1mV
Accuracy: ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range
Input impedance: 400mV > 100MΩ
4V = 10MΩ
40V~600V = 9.1MΩ
DC Volts
Ranges: 400mV, 4V, 40V, 400V, 600V
Resolution: 0.1mV
Accuracy: ±(0.5% rdg + 2 dgt)
Input impedance: 400mV > 100MΩ
4V = 10MΩ
40V~600V = 9.1MΩ
Transient protection: 6kV for 10μ sec
AC Current (50Hz - 60Hz)
Ranges: 40A, 400A
Resolution: 0.01A
Accuracy: ±(2.0% rdg + 6 dgts)
Audible indication: Less than 25Ω
Response time: 500ms
Ranges: 4μF, 40μF, 400μF, 4mF 4.000mF = 4000μF
Resolution: 1.0nF
Accuracy: ±(3% rdg + 10 dgts) on 4μF
±(3% rdg + 5 dgts) on 40μF to 400μF
±(5% rdg + 20 dgts) on 4mF (4000μF)
Minimum input range: >100nF
Minimum input range: "dsc" symbol on LCD indicates that the capacitor must be discharged before testing.
Ranges: 400Ω
Accuracy: ±(1.0% rdg + 4 dgts)
Open circuit volts: -1.2VDC
Overload Protection
Resistance: 500VDC or AC RMS
Continuity: 500VDC or AC RMS
Capacitance: 500VDC or AC RMS
Temperature: 60VDC or 30AC RMS
Range: -30 to 400°F (-34 to 204°C)
Resolution: 0.1°
Accuracy: ±1°F (32 to 120°F); ±0.5°C (0 to 49°C),
±1% + 1.5°F (-4 to 400°F);
±1% + 1°C (-20 to 204°C),
±2% + 4°F (-30 to -4°F);
±2% + 2°C (-34 to -20°C)
Sensor type: K-type thermocouple
Field °F calibration
For accuracies of ±°F, calibrate the Fieldpiece SC45 to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used.
Fieldpiece SC45 calibration
  1. Select the 400°F range.
  2. Remove back case (2 screws on back, one near clamp, other near base). Leave battery cover attached so batteries stay within back case.
  3. Stabilize a large cup of ice water
  4. Immerse the thermocouple probe and let it stabilize
  5. To change the temperature scale to °C, close the jumper just below VR5
  6. Adjust VR5 calibration pot with a small screwdriver to get within 0.1° of 32°F (0°C). Each 1/4 turn should adjust the temperature about 3°, no more than 10° total. There’s no need rotating the screw more than 360°; doing so gets you back to where you started.
  7. Attach case without screws to preview the temperature and continue until you have it dialed in.
Physical Specifications
Display: 3 3/4 digit liquid crystal display (LCD) with a maximum reading of 3999.
Range: Manual ranging mode, hold button for 2 seconds to return to autoranging mode.
Overrange: "OL" or "-OL" mark indication.
Auto power off: 10 minutes
Operating environment: 32 to 122°F (0 to 50°C) at <70% R.H.
Storage temperature: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed.
Accuracy: Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), >75% relative humidity.
Temperature coefficient: 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C).
Power: Two AAA 1.5V batteries
Battery life: 400 hours typical with alkaline
Safety: Designed to meet IEC61010-1 (EN61010-1) and IEC61010-2-032 (EN61010-2-032), clamp is CATIII 300V, class II, voltage Cat.III 600V, and pollution degree 2 indoor use comply with CE, C-tick certified, UL listed
Ordering Information
Model Description Buy Online Price
SC45  Fieldpiece SC45 Mini Clamp Meter with Temperature for HVAC/R Discontinued
See: SC220
Included Accessories
  • 1 - Vinyl Test Leads
  • 1 - Mini Clamp-On Meter Case (ACH4)
  • 2 - 1.5V "AAA" batteries (installed)
  • 1 - Operator’s manual
Optional Accessories
ANC1 Fieldpiece ANC1 4 pocket Deluxe Meter Case Buy Now Sale $12.80
(Reg. $16.00)
ANC3 Fieldpiece ANC3 Large Briefcase-Style Instrument Bag Buy Now Sale $60.00
(Reg. $75.00)
ANC5 Fieldpiece ANC5 Mail Pouch-Style Meter Case Buy Now Sale $8.00
(Reg. $10.00)
ANC7 Fieldpiece ANC7 Large Single Meter Case Buy Now Sale $7.20
(Reg. $9.00)
ANC8 Fieldpiece ANC8 Large Deluxe Meter Case Buy Now Sale $26.40
(Reg. $33.00)
ANC9 Fieldpiece ANC9 Wireless Refrigerant Scale Case Buy Now Sale $16.00
(Reg. $20.00)