- True RMS for accurate readings of non-sinusoidal waveforms
- Built-in non-contact Voltage detector with LED alert
- 2.0" (52mm) jaw size for conductors up to 500MCM
- Dual 40,000/4000 count, backlit LCD display
- Includes Multimeter and Type K Temperature functions
- Inrush function captures transients during motor startups
- Relative Mode for Capacitance Zero and Offset Adjustment
- Data Hold, Peak Hold, MIN/MAX, and Auto Power Off
- Complete with test leads, Type K bead wire temperature probe, 9V battery and carrying case
|

Extech MA1500 Shown
|
| Specifications for Extech MA1500 |
| Specifications |
Range |
Max. Resolution |
Basic Accuracy |
| Display counts |
40,000/4,000 |
| AC Current (True RMS) |
400.00A, 1500.0A |
0.01A |
±(2.8% + 30d) |
| DC Current |
400.00A, 1500.0A |
0.01A |
±(2.5% + 30d) |
| AC Voltage (True RMS) |
400.00mV, 4.000V, 40.00V, 750.0V |
0.01mV |
±(1.0% + 30d) |
| DC Voltage |
400.00mV, 4.0000V, 40.000V, 1000.0V |
0.01mV |
±(0.1% + 4d) |
| Resistance |
400.00Ω, 4.0000kΩ, 40.000kΩ 400.00kΩ, 4.0000 Ω, 40.000MΩ |
0.01Ω |
±(0.5% + 9d) |
| Frequency |
40Hz to 40MHz |
0.001Hz |
±(0.3% + 2d) |
| Capacitance |
400.00nF, 4000nF, 40.00μF, 400.0μF, 4.000mF, 20.00mF, 40.00mF |
0.01nF |
±(3.5% + 10d) |
| Temperature |
-148 to 1832°F (-100 to 1000°C) |
0.1° |
±(1% + 4.5°F/2.5°C) |
| Duty Cycle |
10.0 to 95.0% |
0.1% |
±(1.0% + 2d) |
| Diode |
Yes |
| Continuity |
Yes |
| Dimensions |
11.57x4.13x1.85" (294x105x47mm) |
| Weight |
18.9oz (536g) |
|