Specifications |
|
DC Volts |
Ranges |
660 mV, 6.6 V, 66 V, 660 V, 1000 V |
|
Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
|
Accuracy |
±(0.5 % rdg + 2 dgts) |
|
Overload Protection |
1000 VDC or 750 VACrms |
|
Input Impedance |
660 mV: >100 MΩ;
6.6 V: 10 MΩ;
66 V to 1000 V: 9.1 MΩ |
|
AC Volts |
True RMS |
Applies; 50 Hz - 500 Hz |
|
Ranges |
660 mv, 6.6 V, 66 V, 660 V, 750 V |
|
Basic Accuracy |
660 mV range at 50 Hz to 60 Hz ±(1.5 % rdg
+ 8 dgts)
6.6 V to 660 V ranges: ±(1.5 % rdg + 8 dgts)
750 V range: ±(2.0 % rdg + 8 dgts) |
|
Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
|
Crest Factor |
<3 |
|
Input Impedance |
660 mV: >100 MΩ;
6.6 V: 10 MΩ;
66 V to 750 V: 9.1 MΩ |
|
Overload Protection |
1000 VDC or 750 VACrms |
|
DC Current |
Ranges |
660 uA, 6600 uA, 66 mA, 400 mA, 10 A |
|
Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
|
Accuracy |
660 uA to 400 mA ranges: ±(1.5 % rdg + 2
dgts)
10 A range: ±(3.0 % rdg + 3 dgts) |
|
Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic
fuses |
|
10A Input |
10 A for 60 sec max. followed by a
10 minute cooling period |
|
AC Current |
True RMS |
Applies; 50 Hz - 500 Hz |
|
Ranges |
660 uA, 6600 uA, 66 mA, 400 mA, 10 A |
|
Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
|
Accuracy |
660 uA to 400 mA ranges: ±(2.0 % rdg + 10
dgts)
10 A range: ±(3.5 % rdg + 10 dgts) |
|
Crest Factor |
<3 |
|
Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic
fuses |
|
10A Input |
10 A for 60 sec max. followed by a 10
minute cooling period |
|
Resistance |
Ranges |
660 Ω, 6.6 kΩ, 660 kΩ, 6.6 MΩ, 66 MΩ |
|
Resolution |
0.1 Ω, 1.0 Ω, 10 Ω, 1 kΩ, 10 kΩ |
|
Accuracy |
660 Ωto 660 kΩranges: ±(1.2 % rdg + 5 dgts)
6.6 MΩrange: ±(2.0 % rdg + 5 dgts)
66 MΩrange: ±(3.5 % rdg + 5 dgts) |
|
Open Circuit Voltage (typical) |
-0.45 VDC (-1.2 VDC on 660 Ωrange) |
|
Overload Protection |
500 VDC/ACrms |
|
Capacitance |
Ranges |
6.6 nF , 66 nF, 660 nF, 6.6 uF, 66 uF,
660 uF, 6.6 mF, 66 mF |
|
Resolution |
1 pF, 10 pF, 100 pF, 1 nF, 10 nF, 100 nF, 1
uF, 10 uF |
|
Accuracy |
6.6 nF range: ±(3.0 % rdg + 30 dgts)
66 nF to 660 uF ranges: ±(3.0 % rdg + 5 dgts)
6.6 mF to 66 mF ranges: ±(5.0 % rdg + 20 dgts) |
|
Overload Protection |
500 VDC/ACrms |
|
Frequency |
Ranges |
660 Hz, 6.6 kHz, 66 kHz, 660 kHz, 6.6 MHz,
66 MHz |
|
Resolution |
0.1 Hz, 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz |
|
Accuracy |
±(0.1 % rdg + 3 dgts) |
|
Sensitivity |
10 Hz to 6.6 MHz: >2.5 Vrms,
6.6 MHz to 66 MHz: >2.5 Vrms <5 Vrms |
|
Minimum Pulse Width |
>25 ns |
|
Duty Cycle Limits |
>30 % and <70 % |
|
Overload Protection |
500 VDC/AC rms |
|
Diode Test |
Test Current |
1.2 mA (typical) |
|
Resolution |
1 mV |
|
Accuracy |
±(3.0 % rdg + 3 dgts) |
|
Audible Indication |
<0.03 V |
|
Open Circuit Voltage |
3.5 VDC (typical) |
|
Overload Protection |
500 VDC/ACrms |
|
Continuity Tone |
Audible Indication |
Less than 30 Ω |
|
Response Time |
100 ms |
|
Overload Protection |
500 VDC/ACrms |
General
Characteristics |
Display |
3 3/4 digit, 6600 count LCD |
|
Polarity |
Automatic, positive implied, negative
polarity indication |
|
Overrange |
OL or -OL is displayed |
|
Low Battery Indication |
The battery symbol will display when
battery voltage
drops below operating levels |
|
Measurement Rate |
2 times per second |
|
Auto Power Off |
Approximately 30 minutes |
|
Operating Environment |
t0ºC to 50ºC at <70 % relative humidity |
|
Storage Environment |
-20ºC to 60ºC at 0 to 80 % relative
humidity |
|
Accuracies |
Stated accuracy at 23ºC +5ºC at <75 %
relative humidity |
|
Temperature Coefficient |
0.1 x (specified accuracy) per ºC.
(ºC to 18ºC, 28ºC to 50ºC) |
|
Power |
Single standard 9 volt battery,
NEDA 1604, JIS 006P, IEC 6F22 |
|
Battery Life |
150 hours typical |
|
Dimensions |
165 mm (H) x 78 mm (W) x 42.5 mm (D) |
|
Weight |
Approximately 10.3 oz. (377 g) with battery
and hanger |