Specifications |
|
DC Volts |
Ranges |
200 mV, 2000 mV, 20 V, 200 V 1000 V |
|
Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
|
Accuracy |
±(0.5 % rdg + 1 dgts) |
|
Overload Protection |
10 MΩ |
|
Input Impedance |
1000 VDC or 750 VACrms
(600 VDC/Acrms for 15 seconds on 200 mV range) |
AC Volts
(50 Hz - 500Hz) |
Ranges |
200 mV, 2000 mV, 20 V, 200 V 750 V |
|
Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
|
Accuracy |
200 mV & 20 V ranges: ±(1.2 % rdg + 5 dgts) |
|
200 V & 750 V ranges: ±(2.0 % rdg + 5 dgts) |
|
Overload Protection |
1000 VDC or 750 VACrms
(600 VDC/Acrms for 15 seconds on 200 mV range) |
|
Input Impedance |
10 MΩ |
|
DC Current |
Ranges |
200 uA, 20 mA, 200 mA |
|
Resolution |
0.1 uA, 10 uA, 100 uA |
|
Accuracy |
±(1.0% rdg + 1 dgts) |
|
Input Protection |
0.25 A/500 V fast blow ceramic fuse |
AC Current
(50 Hz - 500Hz) |
Ranges |
200 uA, 20 mA, 200 mA |
|
Resolution |
0.1 uA, 10 uA, 100 uA |
|
Accuracy |
±(1.5% rdg + 5 dgts) |
|
Input Protection |
0.25 A/500 V fast blow ceramic fuse |
|
Resistance |
Ranges |
200 Ω, 2 kΩ, 200 kΩ, 20 MΩ |
|
Resolution |
0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ |
|
Accuracy |
200 Ωto 200 kΩranges: ±(1.0 % rdg + 4 dgts) |
|
20MΩrange: ±(2.0 % rdg + 4 dgts) |
|
Overload Protection |
500 VDC/ACrms |
|
Open Circuit Voltage (typical) |
0.3 VDC (3.0 VDC on 200 Ω) |
|
Capacitance |
Ranges |
200 uF, 2 mF, 20 mF |
|
Resolution |
0.1 uF, 1.0 uF, 10 uF |
|
Accuracy |
±(4 % rdg + 10 dgts) |
|
Overload Protection |
0.25 A/500 V fast blow ceramic fuse |
|
Frequency |
Ranges |
10 Hz to 40 kHz |
|
Resolution |
1 Hz |
|
Accuracy |
±(0.1 % rdg + 3 dgts) |
|
Sensitivity |
3.5 Vrms minimum |
|
Overload Protection |
500 VDC/AC rms |
|
Diode Test |
Test Current |
1.0 mA (typical) |
|
Resolution |
10 mV |
|
Accuracy |
±(1.5 % rdg + 3 dgts) |
|
Open Circuit Voltage |
3.0 VDC (typical) |
|
Overload Protection |
500 VDC/ACrms |
|
Continuity |
Audible Indication |
Less than 100 Ω |
|
Response Time |
100 ms |
|
Overload Protection |
500 VDC/ACrms |
|
Temperature |
Ranges |
-35ºC to 750ºC, -30ºF to 1400ºF |
|
Resolution |
0.1ºC, 0.1ºF |
|
Accuracy |
0ºC to 400ºC ±(1.0 % rdg + 1ºC) |
|
-35ºC to 0ºC, 400ºC to 750ºC ±(3.0 % rdg +
3ºC) |
|
-4ºF to 750ºF ±(1.0 % rdg + 2ºF) |
|
-30ºF to -4ºF, 750ºF to 1400ºF ±(3.0 % rdg
+ 6ºF) |
|
Sensor Type |
K-type thermocouple |
|
Overload Protection |
60 VDC or 30 VACrms |
|
General |
Display |
3 1/2 digit, 2000 count LCD |
|
Polarity |
Automatic, positive implied, negative
polarity indication |
|
Overrange |
OL or -OL is displayed |
|
Low Battery Indication |
The battery symbol will display when
battery voltage drops below operating levels |
|
Measurement Rate |
2.5 times per second |
|
Auto Power Off |
Approximately 25 minutes |
|
Operating Environment |
0ºC to 50ºC at <70% relative humidity |
|
Storage Environment |
-20ºC to 60ºC at 0 to 80% relative humidity |
|
Accuracies |
Stated accuracy at 23ºC +5ºC at
<75% relative humidity |
|
Temperature Coefficient |
0.1 x (specified accuracy) per ºC.
(ºC to 18ºC, 28ºC to 50ºC) |
|
Power |
Single standard 9 volt battery,
NEDA 1604, JIS 006P, IEC 6F22 |
|
Battery Life |
150 hours typical |