Specifications |
|
DC Volts |
Ranges |
400 mV, 4 V, 40 V, 400 V, 1000V |
|
Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
|
Accuracy |
±(1.0 % rdg + 2 dgts) |
|
Overload Protection |
1000 VDC or 750 VACrms |
|
Input Impedance |
400 mV: >100 MΩ; 4 V: 10 MΩ; 40 V to1000 V:
9.1 MΩ |
|
AC Volts |
Ranges |
400 mV, 4 V, 40 V, 400 V, 750V |
|
Basic Accuracy |
400 mV range at 50 Hz to 100 Hz ±(2.0 % rdg
+ 5 dgts) |
|
Resolution |
0.1 mV, 1 mV, 10 mV, 100 mV, 1 V |
|
Input Impedance |
400 mV: >100 MΩ; 4 V: 10 MW; 40 V to 750 V:
9.1 MΩ |
|
Overload Protection |
1000 VDC or 750 VACrms |
|
DC Current |
Ranges |
400 uA, 4000 uA, 40 mA, 400 mA, 10 A |
|
Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
|
Accuracy |
400 uA to 400 mA ranges: ±(2.0 % rdg + 2
dgts)
10 A range: ±(3.0 % rdg + 3 dgts) |
|
Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic
fuses |
|
10A Input |
10 A for 60 sec max. followed by a 10
minute cooling period |
|
AC Current |
Ranges |
400 uA, 4000 uA, 40 mA, 400 mA, 10 A |
|
Resolution |
0.1 uA, 1 uA, 10 uA, 100 uA, 10 mA |
|
Accuracy |
20 mA to 200 mA ranges: ±(2.0 % rdg + 8
dgts)
10 A range: ±(3.5 % rdg + 8 dgts) |
|
Input Protection |
0.5 A/500 V & 10 A/600 V fast blow ceramic
fuses |
|
10A Input |
10 A for 60 sec max. followed by a 10
minute cooling period |
|
Resistance |
Ranges |
400 Ω, 4 kΩ, 400 kΩ, 40 MΩ |
|
Resolution |
0.1 Ω, 1.0 Ω, 100 Ω, 10 kΩ |
|
Accuracy |
400 Ωto 400 kΩranges: ±(1.5 % rdg + 4 dgts)
4 MΩrange: ±(2.5 % rdg + 4 dgts)
40 MΩrange: ±(5.0 % rdg + 4 dgts) |
|
Open Circuit Voltage (typical) |
-0.45 VDC (-1.2 VDC on 400 Ωrange) |
|
Overload Protection |
500 VDC/ACrms |
|
Diode Test |
Test Current |
1.0 mA (typical) |
|
Resolution |
10 mV |
|
Accuracy |
±(3.0 % rdg + 3 dgts) |
|
Audible Indication |
<0.25 V |
|
Open Circuit Voltage |
3.0 VDC (typical) |
|
Overload Protection |
500 VDC/ACrms |
|
Continuity |
Audible Indication |
Less than 25 Ω |
|
Response Time |
500 ms |
|
Overload Protection |
500 VDC/ACrms |
General
Characteristics |
Display |
3 3/4 digit, 3400 count LCD |
|
Polarity |
Automatic, positive implied, negative
polarity indication |
|
Overrange |
OL or -OL is displayed |
|
Low Battery Indication |
The battery symbol will display when
battery voltage
drops below operating levels |
|
Measurement Rate |
2 times per second |
|
Auto Power Off |
Approximately 10 minutes |
|
Operating Environment |
0ºC to 50ºC at <70 % relative humidity |
|
Storage Environment |
-20ºC to 60ºC at 0 to 80 % relative
humidity |
|
Accuracies |
Stated accuracy at 23ºC ±5ºC at <75 %
relative humidity |
|
Temperature Coefficient |
0.1 x (specified accuracy) per ºC.
(ºC to 18ºC, 28ºC to 50ºC) |
|
Power |
Single standard 9 volt battery,
NEDA 1604, JIS 006P, IEC 6F22 |
|
Battery Life |
150 hours typical |
|
Dimensions |
165 mm (H) x 78 mm (W) x 42.5 mm (D) |
|
Weight |
Approximately 10.3 oz. (377 g) with battery
and hanger |