Amprobe Thermometers |
| Specifications |
TH-1 |
TH-3 & THWD-3 |
THWD-5 |
TMD-10 |
TMD90A |
| Type |
Relative Humidity |
Relative Humidity |
Relative Humidity |
Type K&J Thermocouples |
Dual Input, Digital |
| Uses |
Humidity/temperature changes |
Humidity/temperature changes |
Wet bulb, Dew point values, Relative Humidity, Temperature |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature measurements |
| Range |
Humidity |
0 - 100% |
0 - 100% |
0 - 100% |
n/a |
n/a |
| Temp. |
n/a |
n/a |
±0.6°C (±1°F) |
K-type: -200 - 370°C (-328 - 2498°F) J-type: -200 - 1050°C (-328 - 1922°F) |
Dependant on Probe Type: (K, J, T, R, S,
E) |
| Dew Point |
n/a |
n/a |
-73.4 to 59.9°C (-100 to 139.8°F) |
n/a |
n/a |
| Wet Bulb |
n/a |
n/a |
-13.4 to 59.9°C (7.88 to 139.8°F) |
n/a |
n/a |
| Resolution |
n/a |
n/a |
0.1°C / 0.1°F |
0.1°C or °F |
n/a |
| Accuracy |
±3% from 10-95%RH +5% for other RH |
-20 to 60°C ± 0.8°C -4 to 140°F ± 1.6°F |
RH: 0-100% Temp: ±0.6°C(±1°F) |
±(.05% rdg + 0.7°C) ±(.05% rdg + 1.4°F) |
Dependant on Probe |
| More Info |
More>> |
More>> |
More>> |
More>> |
More>> |
|
| |
| Specifications |
THWD-10 |
TMD-50 |
TMD-52 |
TMD-51 |
TMD-53 |
| Type |
0°C to 60°C, (32°F to 140°F)
|
Type K Thermocouples |
Type K/J/T/E Thermocouples |
Type K/J Thermocouples |
Type K/J Thermocouples |
| Uses |
Relative Humidity, Temperature |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature measurements |
| Range |
Humidity |
0 - 100% |
n/a |
n/a |
n/a |
n/a |
| Temp. |
Type K |
-382°F to 1999°F (-200°C to 1372°C) |
Dependant on Probe Type (K/J/T/E) |
K: -100°C to 1372°C (-150°F to 1999°F)
J: -100°C to 1200°C (-150°F to 1999°F) |
K-type: -200-1370°C (-328° - 2498°F)
J-type: -200-1050°C (-328 - 1922°F) |
| Dew Point |
n/a |
n/a |
n/a |
n/a |
n/a |
| Wet Bulb |
n/a |
n/a |
n/a |
n/a |
n/a |
| Resolution |
0.1°C / 0.1°F |
n/a |
n/a |
n/a |
n/a |
| Accuracy |
±2°C on 0°C to 10°C ±0.5°C on 10°C to 45°C ±2°C on 45°C to 60°C ±4°F on 32°F to 50°F ±1°F on 50°F to
113°F ±4°F on 113°F to 140°F |
Dependant on Range |
Dependant on Probe |
Dependant on Probe |
Dependant on Probe |
| More Info |
More>> |
More>> |
More>> |
More>> |
More>> |
|
| |
| Specifications |
TMD-53W |
TMD-55 |
TMD-56 |
TMD-55W |
RTD-10 |
| Type |
Type K/J Thermocouples |
Multilogger Thermometer |
Multilogger Thermometer
|
Multilogger Thermometer |
RTD Thermometer |
| Uses |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature measurements |
Super-Heat/Sub-Cool calculations, Temperature
measurements |
Temperature measurements |
| Range |
Humidity |
n/a |
n/a |
n/a |
n/a |
n/a |
| Temp. |
K-type: -200-1370°C (-328° - 2498°F)
J-type: -200-1050°C (-328 - 1922°F) |
Dependant on Probe Type: (K, J, T,
E, N, R, S) |
n/a |
Dependant on Probe Type: (K, J, T, E, N,
R, S) |
Dependant on Probe |
| Dew Point |
n/a |
n/a |
n/a |
n/a |
n/a |
| Wet Bulb |
n/a |
n/a |
n/a |
n/a |
n/a |
| Resolution |
n/a |
0.1°C/1°C, 0.1°F/1°F |
0.1°C/1°C, 0.1°F/1°F |
0.1°C/1°C, 0.1°F/1°F |
0.1°C to 0.2°F |
| Accuracy |
Dependant on Probe |
Dependant on Probe |
Dependant on Probe |
Dependant on Probe |
Stated accuracy at 23°C ±5°C, <75% R.H. |
| More Info |
More>> |
More>> |
More>> |
More>> |
More>> |
|
| |
| |