<< Amprobe Digital Multimeters
Amprobe PM53A
Compact Commercial DMM with AutoTect and VolTect Discontinued
|
- AutoTect Knows If It Is Measuring AC Volts, DC Volts Or
Resistance
- The AutoTect Feature Has Lower Input Impedance Which Zeros Out
Ghost Voltages
- Measures Capacitance, Frequency, Continuity With Beeper
- VolTect, A Built-In, Noncontact Voltage Detector
- Large Oversize Digital Display
- Overload Protection 450 V dc and V ac rms
- Sensing Average Sensing
- Display And Update Rate 3-5/6 Digits 6000 Counts
- Automatic Power Off (APO) Timing Idle For 3 Minutes
- Low Battery Below Approx 2.4V
|
 
Amprobe PM53-A Shown
|
|
|
|
The PM53A is the essential shirt-pocket size meter. Only 3/8" thick and less
than 3 oz in weight, this meter offers full functionality with ac and dc voltage
to 450 V, resistance to 6 Megohm, capacitance to 100 µF, frequency to 30 kHz
and continuity w/beeper. It also offers VolTect, a built-in, non-contact voltage
detector for ac voltages. Another key feature is AutoTect,™which
automatically selects ac voltage, dc voltage or resistance measurement based on
the test point to which the leads are connected. Fully auto ranging, this
meter offers seven different measurement functions plus features that are
usually found in much more expensive and larger meters. The digital
display is oversized with large digits and unit icons in the display. In
spite of its size, this meter is fully safety rated to CAT III300 V, CAT II 450
V and is UL listed. |
|
|
|
Specifications |
|
DC Voltage |
|
|
Accuracy |
|
Range |
6V |
± (0.5 % + 3 dgt) |
| 60V |
± (1.0 % + 5 dgt) |
| 450V |
± (1.2 % + 5 dgt) |
| NMRR |
> 30 dB @ 50 Hz/60 Hz |
| CMRR |
> 100 dB @ DC, 50 Hz/60 Hz; Rs=1 kW |
| Input
Impedance |
AutoTect Lo-Z V dc: 160 kW, 160 pF nominal |
| V dc
AutoTect threshold |
> +1.2 V dc or < -0.6 V dc nominal |
|
AC Voltage |
Range |
50 Hz - 60 Hz
6V, 60V, 450V |
± (1.5 % + 5 dgt) |
| CMRR |
> 60 dB @ dc to 60 Hz, Rs=1 kW |
| Input
Impedance |
AutoTect Lo-Z V ac: 160 kW, 160 pF nominal |
| ACV
AutoTect threshold |
> 1.5 V ac (50 Hz/60 Hz) nominal |
|
Capacitance |
Range |
100.0 nF, 1000 nF, 10.0 µF,100.0 µF |
±(3.5 %+6 dgt) |
|
Resistance |
Range |
6.000 kW |
± (1.2%+6
dgt) |
| 60.00 kW,
600.0 kW |
± (1.0%+4
dgt) |
| 6.000 MW |
± (2.0%+4
dgt) |
| Open
Circuit Voltage |
0.4 V dc typical |
|
Frequency |
Range |
100 Hz, 1
kHz, 10 kHz |
±(0.5 %+4
dgt) |
|
VolTect |
|
|
Bar Graph Indicator |
|
Typical Voltage |
15 V to
55 V |
- |
| 30 V to
85 V |
-- |
| 55 V to
145 V |
--- |
| 85 V to
190 V |
---- |
| above 120
V |
----- |
|
Indication |
Bar Graph Segments & Audible Beep Tones
Proportional To Field Strength |
|
Detection Frequency |
50/60 Hz |
|
Detection Antenna |
Top left corner of the meter |
|
Audible Continuity Tester |
Open
Circuit Voltage |
0.4 V dc typical |
|
Audible Threshold |
175 Ω ±125 Ω |
|
|
|