DC Voltage |
|
Ranges |
200.0m, 2.000, 20.00, 200.0, 1500V |
1000.0m, 10.00, 100.0, 1500V |
|
Resolution |
0.1mV |
0.1mV in 1000 mV range |
|
Accuracy |
±(0.1% rdg + 2 dgt) |
±(0.1% rdg + 5 dgt) |
|
Input Impedance |
10MΩ |
|
CMRR |
n/a |
>120 dB Up to 1500V dc |
|
NMRR |
n/a |
>60 dB at 50 or 60 Hz |
|
OL Protection |
1500V dc/1000 V ac rms |
|
Transient Protection |
12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001
impulse requirement for at CAT IV 1000 V product. This product
should not be used in installations where transients exceed 12 kV. |
|
AC Voltage |
|
Type |
45 Hz to 2 kHz |
True rms |
|
Measurements |
Ranges |
Accuracy |
Range |
Accuracy |
200 mV to 200 V
(45-500 Hz) |
±(0.8 % rdg+4 dgts) |
1000 mV
(45 Hz to 400 Hz) |
± (1.2 % rdg + 10 dgt) |
200 mV to 200 V
(500 Hz-2 kHz) |
±(1.5 % rdg+5 dgts) |
10 V, 100 V
(45 Hz to 500 Hz) |
± (1.2 % rdg + 10 dgt) |
1000 V
(50-60 Hz) |
±(0.8 % rdg+4 dgts) |
10 V, 100 V
(500 Hz to 2 kHz) |
± (2.0 % rdg + 10 dgt) |
1000 V
(60-500 Hz) |
±(1.5 % rdg+5 dgts) |
1000 V
(45 Hz to 1 kHz) |
± (2.0 % rdg + 10 dgt) |
|
Input Impedance |
10MΩ |
|
Conversion Type |
n/a |
True rms, ac coupled 5% to 100% of range |
|
Crest Factor |
n/a |
≤ 3 |
|
OL Protection |
1500 V dc or 1000 V ac rms |
|
Transient Protection |
12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001
impulse requirement for at CAT IV 1000 V product. This product
should not be used in installations where transients exceed 12 kV. |
|
DC Current |
|
Resolution |
0.1 mV |
0.01µA in 100 µA range |
|
Measurements |
Ranges |
Accuracy |
Range |
Accuracy |
|
200µA to 20mA |
±(0.5%rdg+2dgts) |
100µA range |
±(0.5%rdg+10 dgts) |
|
1000µA to 400mA |
±(2.0%+10 dgts) |
|
200mA to 2A |
±(1.0%rdg+2dgts) |
2A range |
±(2.5%+20dgts) |
|
Input Protection |
- |
2 A/1500 V fast blow ceramic fuse 8×65 mm on A input
, FP700 |
|
Voltage Burden |
250 mV max. (1 mV/1 µA on 200 µA Range)(100 mV/1 mA
on 2 mA Range)
(10 mV/1 mA on 20 mA Range)
(1.5 mV/1 mA on 200 mA Range)
(500 mV/1 A on 2 A Range) |
µA range of 1 mV/1 µA, mA range of 10 mV/1 mA, 2A
range of 500 mV/1A, 500 mV max. (2 V max. on 1000 µA, 100 mA, 400 mA,
2 A ranges) |
|
OL Protection |
A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) (FP 700) |
|
AC Current |
|
Type |
45 Hz to 1 kHz |
True rms |
|
Resolution |
0.1 µA |
0.01µA in 100 µA range |
|
Measurements |
Ranges |
Accuracy |
Ranges |
Accuracy |
|
200 µA to 20 mA |
±(0.8 % rdg+4 dgts) |
100 µA to 100 mA |
± (1.5% rdg + 10 dgts) |
|
400 mA ranges |
± (2.0 % + 10 dgts) |
|
200 mA to 2 A |
±(1.2 % rdg+4 dgts) |
2 A range |
± (2.5 % + 20 dgts) |
|
Voltage Burden |
250 mV max. (1 V on 2 A range) |
µA range of 1 mV/1 µA, mA range of 10 mV/1 mA, 2A
range of 500 mV/1A, 500 mV max. (2 V max. on 1000 µA, 100 mA, 400 mA,
2 A ranges) |
|
Conversion Type |
n/a |
True rms, ac coupled 10% to 100% of range |
|
Crest Factor |
n/a |
≤ 3 |
|
OL Protection |
1500 V dc/1000 V ac rms |
A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) |
|
Resistance |
|
Resistance |
200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ,
20MΩ |
1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 40MΩ |
|
Resolution |
0.1 Ω |
0.01µA in 100 µA range |
|
Measurements |
Ranges |
Accuracy |
Ranges |
Accuracy |
|
200Ω |
±(0.5 % rdg+4 dgts) |
1000 Ω to 1000 kΩ |
± (0.5 % rdg + 8 dgts) |
|
2kΩ to 200kΩ |
±(0.3 %rdg+2 dgts) |
10 MΩ |
± (1.0 % rdg + 10 dgts) |
|
2MΩ |
±(1.0 % rdg+4 dgts) |
40 MΩ |
± (2.0 % rdg + 10 dgts) |
|
20MΩ |
±(2.0 %rdg+4 dgts |
|
Open Circuit Voltage |
200 Ω range |
3.0 V dc typical |
n/a |
|
All other Ranges |
0.3 V dc typical |
|
OL Protection |
1500 V dc or 1000 V ac rms |
|
Continuity
Test |
|
Audible Indication |
n/a |
Less than 40 Ω |
|
Continuity Audible Threshold |
<50Ω ± 25Ω |
n/a |
|
Response Time |
<100 msec |
100 ms |
|
OL Protection |
1500V dc/1000V ac rms |
|
Diode Test (HD110C
only) |
|
Test Current |
1m A dc typical |
|
Test/Open Circuit Voltage |
3.0 V dc Typical |
|
Diode Accuracy |
±(1.5 % rdg+2 dgts) |
|
Capacitance (HD160C
only) |
|
Ranges |
40 ηF, 400 ηF, 4 µF, 40 µF, 400 µF (3999 counts) (Auto/Manual
ranging) |
|
Resolution |
0.01 ηF |
|
Accuracy |
Ranges |
Accuracy |
|
40 ηF, 400 µF ranges |
±(3.0% rdg +10 dgts) |
|
400 ηF to 40 µF ranges |
±(3.0% rdg +5 dgts) |
|
Test Voltage |
< 1 V |
|
Test Frequency |
1.3 Hz on 40 ηF to 40 µF ranges; 0.7 Hz on 400 µF range |
|
OL Protection |
1500V dc or 1000V ac rms |
|
Temperature (HD160C
only) |
|
Ranges |
Ranges |
Accuracy |
|
-20°C ~ 1300°C (-4°F ~ 2372°F) |
3999 counts |
|
Resolution |
1 °C, 1 °F |
|
Accuracy |
-20°C ~ 10°C |
±(2.0% rdg + 4°C) |
|
10°C ~ 200°C |
±(1.0% rdg + 3°C) |
|
200°C ~ 1300°C |
±(2.0% rdg + 2°C) |
|
-4°F ~ 50°F |
±(2.0% rdg + 8°F) |
|
50°F ~ 400°F |
±(1.0% rdg + 6°F) |
|
400°F ~2372°F |
±(2.0% rdg + 4°F) |
|
OL Protection |
1500 V dc or 1000 V ac rms |
|
Frequency (HD160C
only) |
|
Ranges |
100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz |
|
Resolution |
0.01 Hz on 100 Hz range |
|
Accuracy |
±(0.1% rdg + 5 dgts) |
|
Sensitivity |
Ranges |
Accuracy |
|
3 Hz to 1 MHz |
>2.5V ac rms |
|
1MHz to 10MHz |
>2.5V ac rms, <5V ac rms |
|
Min. input range |
100 Hz range |
>3 Hz |
|
1000 Hz range |
>30 Hz |
|
Min. pulse width |
> 25 ns |
|
Duty cycle limits |
> 30% and < 70% |
|
OL Protection |
1500 V dc or 1000 V ac rms |