Specifications |
|
Function |
Range |
Accuracy |
|
DC
Voltage |
|
Measurements |
400 mV, 4V, 40V, 400V, 600V |
±(1.0% rdg + 2 dgts) |
|
Resolution |
0.1 mV |
|
Input Impedance |
2k W/V |
|
Overload protection |
600 VDC or AC rms |
|
AC
Voltage |
|
Measurements |
400 mV, 4V, 40V, 400V, 600V |
|
400 mV (50 ~ 100 Hz) |
±(2.0% rdg + 5 digits) |
|
4, 40, 400, 600V (50~500 Hz) |
|
Resolution |
0.1 mV |
|
Input Impedance |
400 mV: >100 MΩ; 4 V: 10 MΩ; 40 V ~ 600 V: 9.1 MΩ |
|
DC
Current |
|
Measurements |
400 µA, 4000 µA, 40 mA, 400 mA, 10A |
|
400 µA to 400 mA ranges |
±(2.0% rdg + 2 digits) |
|
10 A range |
±(3.0% rdg + 3 digits) |
|
Resolution |
0.1 mV |
|
Voltage Burden |
0.2 V on 400uA, 40mA ranges
2V on 4000 uA, 400 mA ranges |
|
Input Impedance |
0.5 A / 500V fast blow ceramic fuse (FP520)
10 A / 500 V fast blow ceramic fuse (FP540) |
|
AC
Current (50-500 Hz) |
|
Measurements |
400 uA, 4000 uA, 40 mA, 400 mA, 10 A |
|
400 uA to 400 mA ranges |
±(2.5% rdg + 5 digits) |
|
10 A range |
±(3.5% rdg + 5 digits) |
|
Resolution |
0.1 mV |
|
Voltage Burden |
0.2 V on 400uA, 40mA ranges
2V on 4000 uA, 400 mA ranges |
|
Input Impedance |
0.5 A / 500V fast blow ceramic fuse (FP520)
10 A / 500 V fast blow ceramic fuse (FP540) |
|
Frequency (Hz) (50-500 Hz) |
|
Measurements |
400 uA, 4000 uA, 40 mA, 400 mA, 10 A |
|
Resolution |
1Hz |
±(0.1% rdg + 3 dgts) |
|
Sensitivity |
10Hz ~ 400kHz: > 3.5Vrms |
|
Minimum pulse width |
> 2.5us |
|
Duty cycle limits |
>30% and < 70% |
|
Overload protection |
600 VDC or AC RMS |
|
Temperature |
|
Ranges |
-20°C ~ 1000°C, -4°F ~ 1832°F |
|
Resolution |
0.1°C, 0.1°F |
|
|
-20°C ~ 10°C |
±(2.0% rdg + 4°C) |
|
10°C ~ 200°C |
±(1.0% rdg + 3°C) |
|
-20°C ~ 10°C |
±(2.0% rdg + 4°C) |
|
200°C ~ 1000°C |
±(3.0% rdg + 2°C) |
|
-4°F ~ 50°F |
±(2.0% rdg + 8°F) |
|
50°F ~ 400°F |
±(1.0% rdg + 6°F) |
|
400°F ~ 1832°F |
±(3.0% rdg + 4°F) |
|
Sensor type |
K-type thermocouple |
|
Overload protection |
600 VDC or AC RMS |
|
RPM |
|
Ranges: RPM |
600 ~ 4000 RPM |
|
X10 RPM |
4000 ~ 12000 RPM |
|
Resolution |
1 RPM |
±(2% rdg + 4 dgts) |
|
Effect Reading |
> 600 RPM |
|
Overload protection |
600 VDC or AC RMS |
|
% Duty
Cycle |
|
Function |
Range |
Accuracy |
|
|
1.0% ~ 90.0% |
|
Resolution |
0.1% |
|
Pulse width |
> 100us, < 100ms |
±(2% rdg + 5 dgts) |
|
Overload protection |
600 VDC or AC RMS |
|
Dwell
Angle |
|
Number of Cylinders |
4, 5, 6, 8 |
|
Cylinder Accuracy |
4 CYL |
0 ~ 90.0° |
|
5 CYL |
0 ~ 72.0° |
|
6 CYL |
0 ~ 60.0° |
|
8 CYL |
0 ~ 45.0° |
|
Resolution |
0.1° |
±(2% rdg + 5 dgts) |
|
Overload protection |
600 VDC or AC RMS |
|
Continuity |
|
Audible
indication |
Less than 25Ω |
|
Response time |
500ms |
|
Overload protection |
600 VDC or AC RMS |
|
Diode
Test |
|
Test
current |
1.0mA (approximate) |
±(3.0% rdg + 3 dgts) |
|
Resolution |
10mV |
|
Audible indication |
<0.25V |
|
Open circuit volts |
3.0VDC typical |
|
Overload protection |
600VDC or AC RMS |
|
General
Specifications |
|
Display |
3 3/4 digit liquid crystal display (LCD) with a maximum
reading of 3999. |
|
Polarity |
Automatic, positive implied, negative polarity
indication. |
|
Overrange |
(OL) or (-OL) is displayed. |
|
Zero |
Automatic |
|
Low battery indication |
is displayed when the battery voltage drops below the operating leve |
|
Measurement rate |
2 times per second, nominal. |
|
Auto power off |
Approx. 10 minutes. |
|
Operating environment |
0°C to 50°C at < 70% RH. |
|
Storage temperature |
-20°C to 60°C at < 80% RH. |
|
Accuracy |
Stated accuracy at 23°C ± 5°C, <75% RH. |
|
Temperature Coefficient |
0.1 × (specified accuracy) per °C. (0°C to 18°C, 28°C to
50°C) |
|
Altitude |
2000m, indoor operation |
|
Power |
Standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. |
|
Battery life |
150 hours typical with carbon zinc. |
|
Dimensions |
165 × 78 × 50 mm ( 6.5 x 3.1 x 1.9 in.) |
|
Weight |
Approx. 315g (11.1 oz). including holster. |