Specifications |
|
DC Voltage |
Ranges |
400 mV, 4 V, 40 V, 400 V, 1000 V |
|
Accuracy |
all ranges: ±(0.7 % rdg + 1 dgt) |
|
Resolution |
100 µV |
|
Input Impedance |
10MΩ |
|
AC Voltage |
Ranges |
400 mV, 4 V, 40 V, 400 V, 750 V |
|
Accuracy |
4 V Range, 200 Hz to 500 Hz: ±(2.0 % rdg + 4
dgts)
All other ranges: ±(1.5 % rdg + 4 dgts) |
|
Resolution |
100 µV |
|
Input Impedance |
10MΩ |
|
DC Current |
Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
|
Accuracy |
400 µA to 300 mA ranges: ±(1.0 % rdg + 1 dgt)
10 A range: ±(2.0 % rdg + 3 dgts) |
|
Resolution |
0.1 µA |
|
Voltage Burden |
400 µA range: 1 mV/µA
4 mA range: 100 mV/1 mA
40 mA range: 12 mV/1 mA
300 mA range: 4 mV/1 mA
10 A range: 100 mV/1 A |
AC Current
(45 Hz To 500 Hz) |
Ranges |
400 µA, 4 mA, 40 mA, 300 mA, 10 A |
|
Accuracy |
400 µA to 300 mA ranges: ±(1.5 % rdg + 4
dgts)
10 A range: ±(2.5 % rdg + 4 dgts) |
|
Resolution |
0.1 µA |
|
Voltage Burden |
400 µA range: 1 mV/µA
4 mA range: 100 mV/1 mA
40 mA range: 12 mV/1 mA
300 mA range: 4 mV/1 mA
10 A range: 100 mV/1 A |
|
Resistance |
Ranges |
400Ω, 40kΩ, 4MΩ |
|
Accuracy |
400Ω and 40kΩ ranges: ±(1.0 % rdg + 4 dgts)
4MΩ range: ±(1.2 % rdg + 4 dgts) |
|
Resolution |
100 mΩ |
|
Open Circuit Voltage |
400Ω range: 3.0 V dc
All other ranges: 0.5 V dc typical |
|
Capacitance |
Ranges |
4 µF, 40 µF, 400 µF, 4000 µF |
|
Accuracy |
4 µF range: ±(5.0 % rdg + 10 dgts)
40 µF, 400 µF ranges: ±(5.0 % rdg + 5 dgts)
4000 µF range: ±(5.0 % rdg + 15 dgts) |
|
Resolution |
0.1 µF |
|
Test Voltage |
< 3.0 V |
|
Test Frequency |
10 Hz |
|
Input Protection |
µA/mA input: 0.315 A/1000 V fast blow ceramic
fuse 6.3 x 32 mm |
|
Temperature |
Ranges |
-20 °C to 1000 °C, -4 °F to 1832 °F |
|
Accuracy |
-20 °C to 10 °C: ±(2.0 % rdg + 4 °C )
10 °C to 200 °C: ±(1.0 % rdg + 3 °C )
200 °C to 1000 °C: ±(3.0 % rdg + 2 °C )
-4 °F to 50 °F: ±(2.0 % rdg + 8 °F)
50 °F to 400 °F: ±(1.0 % rdg + 6 °F)
400 °F to 1832 °F: ±(3.0 % rdg + 4 °F) |
|
Resolution |
1 °C, 1 °F |
Frequency
(Autoranging) |
Ranges |
4 kHz, 40 kHz, 400 kHz, 4 MHz, 40 MHz |
|
Accuracy |
all ranges: ±(0.1 % rdg + 3 dgts) |
|
Resolution |
1 Hz |
|
Sensitivity |
10 Hz to 4 MHz: > 1.5 V ac rms
4 MHz to 40 MHz: > 2 V ac rms, < 5 V ac rms |
|
Min Pulse Width |
> 25 ns |
|
Duty Cycle Limits |
> 30 % and < 70 % |
|
Continuity |
Audible Indication |
< 35 Ω |
|
Response Time |
100 ms |
|
Diode Test |
Test Current |
1.0 mA (approximate) |
|
Accuracy |
±(1.5 % rdg + 3 dgts) |
|
Resolution |
1 mV |
|
Open Circuit Volts |
3.0 V dc typical |
|
Peak Hold |
AC Volts Accuracy |
40 V to 750 V: ±(3.0 % rdg + 60 dgts)
±(3.0 % rdg + 60 dgts) |
|
AC Current Accuracy |
±(3.0 % rdg + 60 dgts) |
|
Response Time |
> 1 ms |
|
Overload Protection |
AC/DC Voltage |
400 mV range: 1000 V dc or 750 V ac rms 15
sec
All other ranges: 1000 V dc or 750 V ac rms |
|
AC/DC Current |
uA/mA input: 0.315 A /1000 V fast-blow
ceramic (6.3 x 32 mm)
10 A input: 10 A /1000 V fast-blow ceramic (10 x 38 mm)
(10 A for 4 minutes maximum followed by a 12 minute cooling period) |
|
Resistance |
1000 V dc or 750 V ac rms |
|
Continuity |
1000 V dc or 750 V ac rms |
|
Diode Test |
1000 V dc or 750 V ac rms |
|
Capacitance |
0.315 A /1000 V fast-blow ceramic (6.3 x 32
mm) |
|
Temperature |
1000 V dc or 750 V ac rms |
|
Frequency |
1000 V dc or 750 V ac rms |