Specifications |
Details |
|
Insulation Resistance |
Measuring range |
500k through 500G |
|
Test Voltages |
500, 1000, 2500, 5000 VDC |
|
Max. short circuit
measuring current |
Approx. 1.3mA |
|
Scale |
Logarithmic, L=90mm |
|
Accuracy |
+/- 2mm |
|
Test Hold System |
Included |
|
Discharging of line |
Automatic, when "Insulation Test" push
button is NOT pushed |
|
Insulation Resistance |
Measuring Range |
0 - 600 Vac/dc |
|
Input Resistance (DC Voltage) |
3M ohm |
|
Input Resistance (AC Voltage) |
1.35 M ohm |
|
Scale |
Linear, L= 90mm |
|
Accuracy |
+/-% of full scale |
|
Insulation Resistance Input |
600 Volts AC ("Insulation Test" push
button depressed, instrument connected to a voltage source) |
|
Overload Protection:
Voltage Input |
1000 Volts AC or DC (Remove Test
Leads from Voltage source as soon as possible) |
|
General
Specifications |
Power Supply |
4 "D" size Alkaline (IEC
R20's) batteries |
|
Low Battery
Indication |
Red LED |
|
Working Temperature
Range |
0-40°C (32°F to
104°F) |
|
Dimensions (LxWxH) |
9.8" x 13.6" x 5.1" (250mm x 345mm x
130mm) |
|
Weight |
9.9lbs ( 4.5Kg) |
|
Case |
Robust, plastic with Carrying Case |