Specifications |
Details |
|
Function |
Range |
Resolution |
Accuracy |
Overload Protection |
|
AC Voltage |
V- |
600Vms |
1V |
±(1.5% + 3d)
40Hz - 500Hz |
600Vms |
V |
800VDC |
1V |
±(1.0% + 2d) |
800Vms |
|
Input Impedance: 1MΩ// less
than 100pF |
|
AC
Current |
A- |
2000A |
0.1A |
±(3% + 3d)
45Hz - 66Hz |
200A |
|
Adjacent Conductor Influence:
< 0.05A/A |
|
Resistance & Continuity |
Ω |
2000Ω |
1Ω |
±(1% Rdg + 43rdg) |
600Vms |
|
Max. Open Circuit Voltage:
3V |
|
Continuity Check: Beeper
sounds if the resistance of the circuit under test is less than 25Ω. It
will then turn off if the resistance is increased beyond 400Ω. |
Environmental
Conditions |
Calibration |
One-year Calibration cycle |
|
Operating temperature |
32°F to 86°F (0°C to
30°C) ≤
0-80% RH
86°F to 104°F (30°C
to 40°C) ≤
75% RH
104°F to
122°F (40°C to 50°C) ≤
45% RH |
|
Storage temperature |
-4°F to 140°F (-20°C to
60°C) below 80% RH w/ battery Removed |
|
Temperature Coefficient |
0.2x (spec.
Accuracy)/ °C, <18°C, >28°C |
|
Operating Altitude |
6562 Ft |
|
Pollution Degree |
2, Class II |
|
Shock, Vibration: |
Sinusoidal Vibration per MIL-T-28800E (5Hz to 55Hz,
3g Maximum) |
|
General Data |
LCD Display Digits |
3 1/2 digit large scale LCD readout |
|
Display Count |
2000 Count |
|
Measuring Rate |
2.5 times/sec |
|
Overrange Display |
"OL" is displayed for "A" and "Ω" Functions. Show the
real value for "V" function |
|
Batteries type |
Alkaline type 9V Battery |
|
Low battery indication |
A battery
( )
symbol appears the battery should be replaced. |
|
Automatic Shutdown |
After 13 minutes |
|
Battery life |
About 250 hours |
|
Weight (including battery) |
1.85lbs (840 Grams) with Battery |
|
Size |
205(L) x 64 (W) x 39(H)mm |