Amprobe ACDC-3400 IND
CAT IV Industrial True RMS Clamp Meter
|
|
|
- TRMS
- Measures AC Current up to 1000 ACA, Voltage up to 750 VAC /
1000 VDC, Frequency, Resistance and Capacitance and Duty Cycle
- 1000A DC Current
- Peak Hold
- Relative Zero
- Audible continuity
- Auto and manual ranging
- Auto power off
- Data Hold
- Backlight
- Diode Test
- Duty Cycle
- Accommodates conductors up to 2" (51mm) in diameter
- Safety CAT IV 600 V, CAT III 1000 V
|
 
Amprobe ACD-3400 Shown
|
|
|
|
|
|
The Amprobe ACDC-3400 INDCAT IV Industrial True RMS Clamp Meter is ideal for industrial applications and utilities
that require an extra level of safety. Includes True RMS sensing for
accuracy and dependability. Extra large jaw to accommodate wide diameter
wires. |
|
|
| Specifications |
| |
Ranges |
Accuracy |
| DC Volts |
Readings |
660.0 mV, 6.600 V, 66.00 V, 660.0
V, 1000 V |
± (0.5% rdg + 2 dgts) |
| Input impedance |
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66
V to 1000 V: 9.1 MΩ |
| Overload protection |
1000 VDC or 750 VAC rms |
| |
Ranges |
Accuracy |
| DC Current |
Readings |
660.0A |
± (2.0% rdg + 5 dgts) |
| 1000A |
± (3.0% rdg + 5 dgts) |
| Overload protection |
1000A DC |
| AC Volts True RMS |
Readings |
Ranges |
Frequency |
Accuracy |
| 660.0 mV |
50 to 100 Hz |
± (1.5% rdg + 8 dgts) |
| 6.600V, 66.00V |
50 to 500 Hz |
± (1.5% rdg + 8 dgts) |
| 660.0V, 750V |
50 to 500 Hz |
± (1.5% rdg + 8 dgts) |
| Frequency: 10% to 100% of
voltage range |
50 to 1 kHz |
± (0.1% rdg + 5 dgts) |
| Peak Hold |
66.00V, 660.0V, 750V |
50 to 500 Hz |
± (3.0% rdg + 300 dgts) |
| AC coupled TRMS |
5% to 100% of range |
| Crest factor |
≤3 |
| Input impedance |
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66
V to 1000 V: 9.1 MΩ |
| AC Current True RMS |
Readings |
Ranges |
Frequency |
Accuracy |
| 66.00A |
50 to 60 Hz |
± (2.0% rdg + 10 dgts) |
| 66.00A |
61 to 400 Hz |
± (3.0% rdg + 10 dgts |
| 660.0A |
50 to 60 Hz |
± (2.0% rdg + 10 dgts) |
| 660.0A |
61 to 400 Hz |
± (3.0% rdg + 10 dgts) |
| 1000 A |
50 to 60 Hz |
± (2.5% rdg + 10 dgts) |
| 1000 A |
61 to 400 Hz |
± (3.5% rdg + 10 dgts) |
| Frequency: 10% to 100% of current range |
50 to 1kHz |
± (0.1% rdg + 5 dgts) |
| Peak Hold |
66.00A, 660.0A, 1000A |
50 to 400 Hz |
± (3.0% rdg + 200 dgts) |
| AC Coupled TRMS |
5% to 100% of range |
| Crest factor |
≤ 3 |
| Input impedance |
660 mV: >100 MΩ; 6.6 V:10 MΩ; 66
V to 750 V: 9.1 MΩ |
| Overload protection |
1000 VDC or 750 VAC rms |
| |
Ranges |
Accuracy |
| Resistance |
Readings |
660.0Ω, 6.600kΩ, 66.00kΩ, 660.0kΩ |
± (1.0% rdg + 5 dgts) |
| 6.600MΩ |
± (2.0% rdg + 5 dgts) |
| 66.00MΩ |
± (3.5% rdg + 5 dgts) |
| Open circuit volts |
-0.8 Vdc typical , (-1.2 Vdc on
660 Ω range) |
| Overload protection |
1000 VDC or 750 VAC rms |
|
|
|