| Specifications |
| DC Volts |
Ranges |
400mV, 4V, 40V, 400V, 600V |
| Resolution |
0.1mV |
| Accuracy |
±(0.5% rdg + 2 dgts) |
| Input Impedance |
400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ |
| Overload Protection |
600V DC or AC rms to measure millivolts,
use “RANGE “ button to manually select 400mV range. |
AC Volts (50Hz - 500Hz) |
Ranges |
4V, 40V, 400V, 600V |
| Resolution |
1mV |
| Accuracy |
±(1.2% rdg + 5 dgts) ±(2% rdg + 5 dgts) on
600V range |
| Input Impedance |
4V:10MΩ;40V~600V:9.1MΩ |
| Overload Protection |
600V DC or AC rms |
AC Current (50Hz - 60Hz) |
Ranges |
40A , 400A |
| Resolution |
0.01A |
| Accuracy |
±(2.0% rdg + 10 dgts) 50 ~ 60Hz |
| Overload Protection |
400A AC |
| Resistance |
Ranges |
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
| Resolution |
0.1Ω |
| Accuracy |
±(1.0% rdg + 5 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 5 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on
40MΩ range |
| Open Circuit Volts |
-0.45V DC typical, (-1.2Vdc on 400Ω range) |
| Overload Protection |
600V DC or AC rms |
| Capacitance |
Ranges |
4uF , 40uF , 400uF , 4mF |
| Resolution |
1nF |
| Accuracy |
±(3.0% rdg + 15 dgts) |
| Minimum Input Range |
>100nF |
| Overload Protection |
600V DC or AC rms when the capacitor to be
tested is connected, if “dsc” symbol is indicated on LCD, it
means there is voltage existing in the tested capacitor and
needs to be discharged before testing. |
| Temperature |
Ranges |
-30°F ~ 400°F, -35°C ~ 400°C |
| Resolution |
0.1°F, 0.1°C |
| Accuracy |
±(1% + 2°F) 32°F ~ 400°F ±(1% + 1°C) 0°C ~
200°C ±(2% + 6°F) -30°F ~ 32°F ±(2% +3°C) -35°C ~ 0°C |
| Sensor Type |
K-type thermocouple |
| Overload Protection |
60V DC or 30V AC rms |
| Continuity |
Range |
-30°F ~ 400°F, -35°C ~ 400°C |
| Resolution |
0.1°F, 0.1°C |
| Audible Indication |
±(1% + 2°F) 32°F ~ 400°F ±(1% + 1°C) 0°C ~
200°C ±(2% + 6°F) -30°F ~ 32°F ±(2% +3°C) -35°C ~ 0°C |
| Response Time |
K-type thermocouple |
| Overload Protection |
60V DC or 30V AC rms |
| Non-Contact Voltage Indicator |
Senses voltage 70V to 600VAC (50Hz ~ 60Hz),
beeper chirps and big bright red LED comes on, works when meter
dial is on any range. |
| Display |
3¾ digit liquid crystal display (LCD) with a
maximum reading of 3999. |
| Polarity |
Automatic, positive implied, negative
polarity indication. |
| Overrange |
(OL) or (-OL) is displayed. |
| Auto power off |
Approx. 10 minutes. |
| Low battery indication |
The “
"is
displayed when the battery voltage drops below the operating level |
| Auto power off |
Approx. 10 minutes |
| Measurement rate |
2 times per second, nominal. |
| Operating Environment |
0°C to 50°C / 32°F to 122°F at <70% relative
humidity. |
| Temperature Coefficient |
0.1 × (specified accuracy) per °F, (32°F to
66°F, 82°F to 122°F). |
| Jaw opening capability |
30mm (1.18 in) conductor. |
| Power |
1.5 volt battery x2, R03/SIZE AAA. |