Features |
Range |
Accuracy |
| AC
Voltage |
50Hz - 500Hz |
400.0 mV |
4.0% + 5 digits |
|
Selection by RANGE button manually, and is specified
from AC 40mV (AC 60mV for True RMS model ACD-6 TRMS-PRO) and up
|
| 50Hz -- 60Hz
|
4.000V, 40.00V, 400.0V |
2.0% + 5 digits |
| 60Hz -- 500Hz |
4.000V, 40.00V, 400.0V |
2.5% + 5 digits |
| 50Hz -- 500Hz |
600V |
3.0% + 5 digits |
| CMRR |
>60dB @ DC to 60Hz, Rs=1kΩ |
| Input
Impedance |
10MΩ, 30pF nominal |
|
DC Voltage |
General Stats |
400.0 mV
4.000V, 40.00V, 400.0V
600V |
1.0% + 3 digits
1.7% + 3 digits
2.0% + 3 digits |
| NMRR |
>50dB @ 50/60Hz |
| CMRR |
>120dB @ DC, 50/60Hz, Rs=1kΩ |
| Input
Impedance |
10MΩ, 30pF nominal (1000MΩ for 400.0mV range) |
| AC Current
(Clamp-on) |
50Hz / 60Hz |
400.0A |
1.5% + 5 digits |
|
1000A |
1.5% + 5 digits |
|
Audible Continuity Tester |
Open Circuit
Voltage
(0.4VDC typical) |
400.0 mV
4.000V, 40.00V, 400.0V
600V |
1.0% + 3 digits
1.7% + 3 digits
2.0% + 3 digits |
| NMRR |
>50dB @ 50/60Hz |
| CMRR |
>120dB @ DC, 50/60Hz, Rs=1kΩ |
| Input
Impedance |
10MΩ, 30pF nominal (1000MΩ for 400.0mV range) |
|
Resistance |
General Stats |
400.0Ω |
1.5% + 6 digits |
|
4.000kΩ, 40.00kΩ, 400.0kΩ |
1.0% + 4 digits |
|
4.000MΩ |
1.5% + 4 digits |
|
40.00MΩ |
2.5% + 4 digits |
| Open Circuit
Voltage |
0.4VDC typical |
|
Diode
Tester |
Open Circuit < 1.6 VDC |
|
Voltage Test Current (Typical) 0.4mA |
|
Sensing |
Average Sensing |
|
Safety |
Meets EN61010-1:2001; IEC61010-2-032(1994), EN61010-2-032(1995),
UL3111-2-032(1999). Category III 600 Volts AC & DC. |
| Transient
protection |
6.5kV (1.2/50μs surge) for all models |
| Update Rate |
3 per second nominal |
| Polarity |
Automatic |
| Altitude |
Operate below 6,562ft (2000m) |
| Pollution |
2 |
|
Overload Protections |
ACA Clamp-on jaws : AC 1000A rms continuous + & COM
terminals (all functions) : 600VDC/VAC rms |
|
Climatic Conditions |
Reference temperature |
23°
± 5°C |
| Temperature
Coefficent |
nominal 0.15 x
(specified accuracy)/°C @ 0°C -18°C or 28°C -40°C (32°F - 64°F OR
82°F - 104°F), or otherwise specified |
|
Operating temperature |
0°C TO
40°C (32°F TO 104°F) |
|
Relative humidity |
Maximum relative
humidity 80% for temperature up to 31°C decreasing linearly to 50%
relative humidity at 40°C |
|
Storage temperature |
-20°C to 60°C (-4°F
to 140ºF), < 80% R.H. (with battery removed) |
|
Storage humidity |
<80%
RH |
|
Power Supply |
Battery type |
One 3V
coin battery (ANSI/NEDA-5004LC, IEC-CR2032) |
|
Power Consumption |
2.2 mA
typical |
|
Low battery |
Below approx. 2.4V |
|
Battery life |
About 90 hours of continued measurement |
|
APO Timing |
Idle
for 30 minutes |
|
APO Consumption |
190μA
typical on voltage & current functions |
|
Mechanical Characteristics |
Size |
L224mm
X W78mm X H40mm |
|
Weight |
220 gm
approx |
|
Jaws opening |
45mm
max |
|
EMC |
Meets EN61326
In an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 45 digits
Performance above 3V/m is not specified
|