Test Equipment Depot - 800.517.8431

Test Equipment Catalog Specials  Repair Surplus Ordering/Contact Info

 

Amprobe
Amprobe Catalog | Amprobe Price List

 

<< Amprobe Digital AC Clamp Meters

Amprobe ACD-40PQ and ACD-41PQ
1000A Clamp-on PQ Meter with Total Harmonics Distortion Measurement

  • TRMS sensing
  • Total Harmonics Distortion THD, AC/DC Voltage up to 600V, AC Current up to 1000A, Resistance, Frequency, Temperature
  • ACD-41PQ also measures Active (W),Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout
  • AutoVA- Auto Selection of AC Volts, DCVolts or AC Amps (ACD-41PQ)
  • Data-logging 5400 points (ACD-40PQ)
  • Optional PC interface capability
  • Audible continuity
  • Auto power off
  • Automatic polarity
  • Low battery indication
  • Peak hold (ADC-41PQ)
  • Data hold
  • Large, easy to read LCD display with backlight
  • Accommodates conductors up to 1.77" (45mm) in diameter
  • Carrying case, test leads, batteries (installed), thermocouple and manual included
  • Voltage overload protection for all functions up to 600V AC/DC
  • Safety CATIII 600V

Click here for a larger image of the Amprobe ACD-40PQ ShownClick here for larger image
Amprobe ACD-40PQ Shown

Product Information

Datasheet 343 KB
Specifications HTMLClick to jump to...
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
PDF Help
The ACD-40's provide a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data logging feature or get complete Power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.

Features ACD-40PQ ACD-41PQ Basic Accuracy
TRMS Measurement Yes -
AC Current 40.0 / 400.0 / 1000A  ±(1.0% Rdg + 5 LSD) @ 50 / 60Hz
DC Voltage 600.0V ±(0.5% Rdg + 5 LSD)
AC Voltage 600.0V ±(0.5% Rdg + 5 LSD) @ 50 / 60Hz
Resistance 999.9 Ohms ±(1.0% Rdg + 6 LSD)
Frequency 5.00 Hz to 500.0 Hz ±(0.5% Rdg + 4 LSD)
Active Power (W) - 0 to 600.0 kW ±(2.0% Rdg + 6 LSD) @ Harmonics
Fund to 10th & PF > 0.7
Reactive Power (VAR) - 0 to 600.0 kVAR ±(2.0% Rdg + 6 LSD) @ Harmonics
Fund to 10th & PF > 0.7
Apparent Power (VA) - 0 to 600.0 kVA ±(2.0% Rdg + 6 LSD) @ Harmonics
Fund to 10th
Power Factor - 0.10 to 0.99 ±3 LSD) @ Harmonics Fund to 21th
THD-R 0.0% to 99.9%   1.5% of Reading + 6d @ Fund Frequency
THD-F   0.0% to 99.9% 1.5% of Reading + 6d @ Fund Frequency
Temperature -58 F to 572 F
(-50 C to 300 C)
±(2.0% Rdg + 6F)
±(2.0% Rdg + 3C)
Hi-Lo Logging 5400 Points - -

General Specifications

Display Voltage functions: 6000 counts LCD display(s)
Power, Ohm & Hz functions 9999 counts LCD display(s)
ACA clamp-on function 4000 counts LCD display(s)
Update Rate: Power function: 1 per second nominal (ACD-41PQ only)
Voltage, ACA clamp-on, Ohm, Hz &Temperature functions: 4 per second nominalACD-40PQ Hz function: 2 per second nominal.
Polarity: Automatic
Low Battery: Below approx. 2.4V
Operating Temperature: 0°C to 40°C
Relative Humidity: Maximum relative humidity80% for temperature up to 31°C decreasing linearly to 50% relative humidity at 40°C
Altitude: Operating below 2000m
Storage Temperature: -20°C to 60°C, < 80%R.H. (with battery removed)
Temperature Coefficient: nominal 0.15 x (specified accuracy)/ °C @ (0oC -18oC or28°C -40°C), or otherwise specified
Sensing: True RMS sensing for all models
Safety: Meets IEC61010-2-032 (1994), EN61010-2-032(1995), UL3111-2-032(1999).
Measurement Category: III 600 Volts ac & dc
Transient protection: 6.5kV (1.2/50µs surge) for all models
Pollution degree 2
E.M.C.: Meets EN61326(1997, 1998/A1),EN61000-4-2(1995), and EN61000-4-3(1996)
In an RF field of 3V/m: Total Accuracy = Specified Accuracy + 45 digits Performance above 3V/m is not specified
Overload Protections ACA Clamp-on jaws: AC 1000ARMS continuous + & COM terminals (all functions):600VDC/VAC RMS
Power Supply: standard 1.5V AAA Size (NEDA24Aor IEC LR03) battery X 2
Power Consumption: Voltage, ACA, Hz & Power functions: 10mAtypical (ACD-41PQ)
Power Supply: standard 1.5V AAA Size (NEDA24Aor IEC LR03) battery X 2
Power Consumption: Voltage, ACA, Hz & Power functions: 10mAtypical (ACD-41PQ)
Voltage & ACA functions: 3.5mAtypical (ACD-40PQ )
Ohm & Temperature functions: 4mAtypical
APO Timing: Idle for 16 to 17 minutes
APO Consumption: 10µAtypical
Physical Specifications Dimension: L224mm X W78mm X H40mm
Weight: 224 gm approx
Jaw opening & Conductor diameter: 45mm max
Special features ACD-41PQ Backlight display ;AutoVATM (Auto Selection on ACV, DCV or ACA functions); Power measurement of selectable W, VAR & VA with dual-display Total Power Factor features; Total harmonic distortion THD%-F; PEAK-RMS HOLD;
ACD40PQ Backlight display; THD%-R Total harmonic distortion-RMS); Onscreen stand-alone Hi-Lo logging (5400 minutes) at sampling speed of faster than: 20 per second for Voltage & ACA functions 4 per second for Ohm & Temperature functions 2 per second for Hz function
Electrical Specifications Accuracy is ±(% reading digits + number of dig-its) or otherwise specified, at 23 °C ±5 °C& less than 75% R.H. True RMS (all models)ACV & ACA clamp-on accuracies are specified from 0% to 100% of range or otherwise specified. Maximum Crest Factor is as specified below, and with frequency spectrums, besides fundamentals, fall within the meter specified AC bandwidth for non-sinusoidal waveforms. Fundamentals are specified at 50Hz and 60Hz.
 
Ordering Information
Model Description Buy Online List Price
ACD40PQ Amprobe ACD-40PQ 1000A Clamp-on PQ Meter with Total Harmonics Distortion measurement  Discontinued
ACD41PQ  Amprobe ACD-41PQ 1000A Clamp-on PQ Meter with Total Harmonics Distortion measurement  Buy Now $263.96
(Reg. $299.95)
Included Accessories
 
  • Test leads
  • Batteries
  • Carrying Case
  • Instruction Manual
Included
Optional Accessories
RS232KIT2  Amprobe RS-232 KIT2 Data Recording System for Digital Multimeters or Clamp-ons  Buy Now $48.95
(Reg. $49.95)
DKTA620  Amprobe DKTA-620 Single to Dual Temperature Adapter  Buy Now $29.35
(Reg. $29.95)
TPK56  Amprobe TPK-56 Bead Type-K Thermocouple  Buy Now $15.63
(Reg. $15.95)
TL36A  Amprobe TL36A Test Lead set w/ Alligator Clip, Cat III 1kV  Buy Now $12.69
(Reg. $12.95)
Replacement Parts (Included with Product)
MTL90B  Amprobe MTL-90B Set of Test Leads with Alligator Clips (alligator clips are not supplied with included accessories)  Buy Now $16.61
(Reg. $16.95)
TPK59  Amprobe TPK-59 Thermocouple  Buy Now $17.59
(Reg. $17.95)
 

Amprobe Catalog   |  Amprobe Price List

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved