| Specifications |
| DC Volts |
Ranges |
400mV, 4V, 40V, 400V, 600V |
| Resolution |
0.1mV |
| Accuracy |
±(0.5% rdg + 2 dgts) |
| Input Impedance |
400mV:>100MΩ; 4V:10MΩ;40V~600V:9.1MΩ |
| Overload Protection |
600VDC or AC rms To measure millivolts, use
“RANGE “ button to manually select 400mV range. |
| AC Volts (50hz - 500hz) |
Ranges |
4V, 40V, 400V, 600V |
| Resolution |
1mV |
| Accuracy |
±(1.2% rdg + 5 dgts) |
| Input Impedance |
4V:10MΩ;40V~600V:9.1MΩ |
| Overload Protection |
600 VDC or AC rms |
| AC Current (50hz - 60hz) |
Ranges |
40A , 400A |
| Resolution |
0.01A |
| Accuracy |
±(2.0% rdg + 6 dgts) 50 ~ 60Hz |
| Overload Protection |
600 VDC or AC rms |
| Resistance |
Ranges |
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
| Resolution |
0.1Ω |
| Accuracy |
±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges |
| ±(1.5% rdg + 4 dgts) on 4MΩ range |
| ±(3.0% rdg + 5 dgts) on 40MΩ range |
| Open Circuit Volts |
-0.45V dc typical, (-1.2Vdc on 400Ω range) |
| Overload Protection |
600VDC or AC rms |
| Continuity |
Ranges |
400Ω |
| Resolution |
1Ω |
| Audible Indication |
Less than 25Ω |
| Response Time |
500ms |
| Overload
Protection |
600VDC or AC rms |
| Capacitance |
Ranges |
4uF , 40uF , 400uF , 4mF |
| Resolution |
1nF |
| Accuracy |
±(3.0% rdg + 15 dgts) on 4uF range |
| ±(3.0% rdg + 5 dgts) on 40uF to 400uF ranges |
| ±(5.0% rdg + 20 dgts) on 4mF range |
| Minimum Input Range |
>100nF |
| Overload Protection |
600VDC or AC rms When the capacitor to be
tested is connected, if “dsc” symbol indicates on LCD, it means
there is voltage existing in the tested capacitor and need to be
discharged before testing. |
| Temperature |
Ranges |
-30°F ~ 400°F, -35°C ~ 400°C |
| Resolution |
0.1°F, 0.1°C |
| Accuracy |
±(1% + 2°F) -4°F ~ 400°F ±(1% + 1°C) 0°C ~
200°C |
| ±(2% + 4°F) -30°F ~ -4°F ±(2% +3°C) -35°C ~
0°C |
| Sensor Type |
K-type thermocouple |
| Overload Protection |
60VDC or 30VAC rms |
| Accuracy |
Stated accuracy at 74°F ±8°F, <75%
relative humidity. |
| Display |
3¾ digit liquid crystal display (LCD) with a maximum reading of 3999 |
| Polarity |
Automatic, positive implied, negative
polarity indication |
| Overrange |
(OL) or (-OL) is displayed |
| Zero |
Automatic. |
| Low Battery Indication |
The " " is displayed when the battery voltage
drops below the operating level. |
| Auto Power Off |
Approx. 10 minutes. |
| Measurement Rate |
2 times per second, nominal |
| Operating Environment |
0°C to 50°C / 32°F to 122°F at <70% relative
humidity |
| Storage Temperature |
-20°C to 60° / -4°F to 140°F, 0 to 80%
R.H. with battery removed from meter |
| Temperature Coefficient |
0.1 × (specified accuracy) per °F,(32°F
to 66°F, 82°F to 122°F) |
| Altitude |
6561.7 Feet (2000m) |
| Jaw Opening Capability |
30mm (1.18 in) conductor |