Test Equipment Depot Top Nav Bar
Test Equipment Depot - 800.517.8431 Free Ground Shipping Offer
<< Ametek Catalog
<< Ametek Signal Calibrators

Ametek ASC300G
Advanced Signal Calibrator
Discontinued

  • Dry Block Calibrator (122 to 1202°F) 50 to 650°C, Enhanced
  • Dual-Zone Heating Block-ensures temperature homogeneity throughout the block. Performance equivalent to liquid temperature bath
  • Enhanced Accuracy and Stability by the built-in reference sensor. MVI circuitry ensures stability despite mains supply variations
  • Universal Inputs-handles multiple type temperature sensors, no need for multiple instruments.
  • Automatic, stand alone calibration system.
  • Upload/download your calibration routines
  • NIST traceable certificate

Click here for larger image - Ametek ASC300 Advanced Signal Calibrator with standard NIST  traceable certificateClick here for larger image - Ametek ASC300 Advanced Signal Calibrator with standard NIST  traceable certificate
Ametek ASC300
Shown

 

Product Information
Datasheet 1.7 MB
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information

PDF Help

 
The ASC300 is substantial enough to cover all needs for a process signal calibrator with superior accuracy and com-pact enough to fit into the tool box and operate with one hand for easy field calibration.

The ASC-300 can change the entire calibration regimen for signal, pressure, and temperature. It may be combined with the APM external pressure modules or a Ametek dry-block calibrator to meet any calibration needs.

This signal calibrator combines a full numerical keypad with a series of function keys and a graphical user interface making it easy to perform various tasks in a short period of time. This advanced calibrator employs the latest technology in supporting your calibration needs.

This product measures and sources: TCs, RTDs, current, voltage, frequency, and pulse trains. It is also designed to be compatible with the APM pressure modules and thus offering multi-function operability. There are two channels of operation providing the user with an isolated read-back circuit. The graphical display makes it is easy to recognize the status of the instrument, take readings, and simulate different functions.
 
Options

Details

Read-back display The upper half of the graphical display is dedicated to the read-back signal from the device-under-test. This input section is electrically isolated from the circuitry. You can also read pressure from the Ametek APM pressure modules in this display section.
Primary display This part is used for all input or output combinations. The primary display plus the read-back display gives a full comprehensive and simultaneous input-output functionality and an excellent overview of the test in progress.
Soft Keys Three navigation keys. Their function is clearly explained in the bottom of the display.
Backlight ON / OFF Turn the back light on in dark environments.
Numeric keyboard A full numeric keyboard gives you the absolute fastest way to reach your desired set values.
Terminal block All input and output connectors are placed away from the display and keyboard to give you the maximum freedom to operate the unit.
"Never get lost" - HOME key This key sends you immediately back to the main operating display without making any changes to the setup.
Communication connection Small stereo jack connector for the serial communication inter-face.
Fast stepping keys Just one push of a button and you can output null (0%) or full span (100%) of your desired range. The 25% button cycles the output in 25% steps up or down each time you push it.
Pressure modules LEMO connector in the bottom of the instrument to provide easy connection for the entire range of Ametek APM pressure modules.
 
Simultaneous input and output
The Ametek ASC300 offers simutaneous input and output. This means that you can calibrate and adjust a tempera-ture transmitter on the table with no other necessary instruments.

Output the sensor signal and input the mA from the trans-mitter. If you select mA Loop the Ametek ASC300 will also supply the 24 VDC for the loop. In the display you will see both your output temperature and the return mA from the transmitter. Enter the zero and full scale values and you can make quick 25% steps or go direct to zero or full span values. The Ametek ASC300 has dedicated keys for this operation so adjustment on the transmitter is made easier.

Temperature reading at reference level
The Ametek ASC300 offers the possibility to characterize an RTD sensor. Use this feature to add a missing special curve or to characterize a reference RTD.

If you choose a reference RTD from the Ametek STS100 series of high accurate and stable temperature sensors, they will be delivered with a traceable calibration certificate including the necessary Van Dusen coefficients. Enter the figures into the JOFRA ASC300 and you have a temperature reference. Complement this with a Ametek dry-block temperature calibrator and your Ametek ASC300 becomes the heart of your portable calibration lab.

Fuseless protection
If you, by mistake, connect the Ametek ASC300 to the mains supply, the instrument is protected with a fuseless protection feature. This feature protects the instrument on up to 240 VAC on any combination of connections made on the test lead connectors and prevents expensive repairs and recalibration of the instrument.

JOFRACAL Calibration Software
The JOFRACAL calibration software ensures easy calibration of RTD´s, thermocouples, transmitters, thermoswitches, pressure gauges and pressure switches. JOFRACAL can be used with Ametek DPC-500, APC, CPC and IPI pres-sure calibrators, all Ametek temperature calibrators, as well as Ametek AMC900, ASC300 multi signal calibrator and ASM-800 signal multi scanner.
Requirements

Details

Minimum Requirements:
Hardware
  • Intel Pentium II 1.4 GHz Processor
  • 64MB Ram (128MB recommended)
  • 80MB free disk space on hard disk (120MB recommended) prior to installation
  • Standard VGA (800x600, 256 colors). 1024x768 Recommended
  • CD-Rom Drive for installation of program
  • 1 or 2 free RS-232 serial ports, depending on configurations
Minimum Requirements:
Software
  • Microsoft Windows 98, Microsoft Windows NT 4.0, Microsoft Windows 2000,
  • Microsoft Windows ME, Microsoft Windows XP, Windows Vista\
  • System fonts: MS Sans Serif, Arial
Calibration Software:   View PDF

JOFRACAL calibration software may also be used for manual calibrations, as it can be set up to accept manual entry of calibration data together with other liquid baths, ice points or dry-block heat sources. The calibration data collected may be stored on a PC for later recall or analysis. The ITC calibrator stores the calibration procedure and may be taken out to the process site without using a personal computer. Once all calibrations are completed, the data may be uploaded to the JOFRACAL calibration software for post-processing and printing of certificates. The calibration data collected may be stored on the personal computer for later recall or analysis.

 
Modes

Details

Resistance Temperature Detector - RTD

Response Time

<5 mSec

Connection

2, 3, and 4-wire

Ohm

Range 12 month Accuracy
min max
ohm read (low) 0.0Ω 400.0Ω 0.025% rdg ± 0.05Ω
ohm read (high) 0.0Ω 4000.0Ω 0.025% rdg ± 0.5Ω
ohm source (low) 0.1 to 0.5 mA 5.0Ω 400.0Ω 0.025% rdg ± 0.01
0.5 to 3 mA 0.025% rdg ± 0.05Ω
ohm source (high) @0.1 to 0.5 mA 400.0Ω 1500.0Ω 0.025% rdg ± 0.05Ω
@0.5 to 3 mA 1500.0Ω 4000.0Ω
RTD Types Pt10, Pt25, Pt50, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50, Cu100, Ni120, YSI400
More Info Click for RTD Type Input Chart >>

Thermocouple - TC

Cold Junction Compensation ON/OFF Control

Yes

Thermocouple mV

Range Accuracy
(12 months)
Min Max
TC mV Read -10.000 mV 75.000 mV 0.02% rdg ± 10µV
TC mV Source -10.000 mV 75.000 mV 0.02% rdg ± 10µV
Output

Maximum current output is 1 mA with an output impedance of = 1 Ω

Thermocouple Cold Junction

Range Accuracy
(12 months)
Min Max
CJC compensation 18 °C (64 °F) 28 °C (83 °F) 0.20 °C (0.36 °F)
CJC outside above - - 0.05 °C (0.09 °F)
TC Type B, C, E, J, K, L, N, R, S, T, U, BP, XK
More Info Click for Thermocouple Input Chart >>

Volt (V)

Range Accuracy
(12 months)
Min Max
Read (isolated) 0.000V 30.000V 0.015% rdg + 2mV
Read (non-isolated) 0.000V 20.000V
Source

Frequency
Pulse

Range Accuracy
(12 months)
Min Max
CPM read 2.0 600.0 0.005% rdg + 0.1 CPM
Hz read 1.0 1000.0 0.05% rdg + 0.1Hz
KHz read 1.00 10.00 0.05% rdg + 0.01 KHz
CPM Source 2.0 600.0 0.05%
Hz source 1.0 1000.0 0.05%
KHz source 1.0 10.0 0.125%
Pulse (source only)
Rate: 2 CPM to 10 KHz
1 30000  
ASC-300 Specifications
Temperature range

Operating Temperature

-10 to 50°C / 14 to 122°F
Storage Temperature -20 to 70°C / -4 to 158°F
All specifications specified at ambient temperature 23°C ±5°C / 73°F ±9°F
Outside ambient 23C ±5°C ±0.005% rdg/°C
Outside ambient 73°F ±9°F ±0.0028% rdg/°F
Power supply

Battery

AA Alkaline (x4)

Re-chargeable battery pack optional
Low Battery Indicator Yes
RS232 communication interface Connector Stereo jack
Communication rate 9600 baud, ASCII
Electrical interface ±5 V non isolated
 
Ordering Information
Model Description Buy Online Price
ASC300G Ametek ASC300 Advanced Multi-Signal Process Calibrator with NIST traceable certificate Discontinued
Included Accessories
 
  • 1 - Traceable calibration certificate
  • 1 - Reference manual
  • 4 - Battery set (AA)
  • 1 - Test leads
  • 1 - Soft carrying case
  • 1 - Shoulder strap

Included

Optional Accessories
123958  Ametek 123958 Serial Cable - Serial to Serial Connection  Buy Now Sale $32.30
(Reg. $34.00)
SPKASC002  Ametek SPK-ASC-002 Rechargable Battery Kit  Buy Now Sale $78.85
(Reg. $83.00)
SPKASC003  Ametek SPK-ASC-003 Charger for the rechargeable battery pack (115/230 VAC)  Buy Now Sale $321.10
(Reg. $338.00)

Ametek Catalog   |   Ametek Price List

$40.00 Minimum on Total Order