<< Ametek Catalog << Ametek Handheld Pressure Calibrators |
| |
Ametek HPC502 Handheld Pressure Calibrator Dual sensor |
- Dual sensor high accuracy pressure calibrator
- mA measurement
- Voltage measurement
- 24 VDC transmitter supply
- High speed pressure switch test
- High speed min./max. hold
- Temperature measurement with external RTD sensor
- JOFRA APM pressure module connection
- RS232 communication
- On-line calculation of sensor error %
- Automatic leak test timer function
- Delta/sum calculation on pressure measurements
- Display contrast adjustment
- Instrument setup lock
- Storage of 5 setups
- Setup of automatic off timer
- Setup of no. of display windows/measurement channels
- Select display high or low resolution
- Setup of backlight timer
- HART resistor on/off
- Normal or dampened display update rate
|
 
Ametek HPC502 Shown
|
|
|
| |
| HPC502 Specifications |
| Pressure; gauge / compound ranges |
bar |
-0.96 to 1 and 2 -0.82 to 7, 20 and 35 |
| psi |
-14 to 15 and 30 -12 to 100, 300 and 500 |
| Pressure; gauge |
bar |
70, 200, 350 and 700 |
| psi |
1,000. 3,000, 5,000 and 10,000 |
| Pressure; absolute ranges |
bar |
0.025 to 1.1 and 2 0.07 to 7 and 20 |
| psi |
0.35 to 16 and 30 1 to 100 and 300 |
| Engineering units (built-in) |
User selectable |
15 units |
Pressure accuracy ambient temp. (18 to 28°C / 65 to 82°F) |
±25 mbar / 0.35 psi |
±0.025% F.S. |
| ±70, 350 mbar / 1, 5 psi |
±0.05% F.S. |
| All other pressure ranges |
±0.025% RDG + 0.01% F.S. |
| Vacuum |
±0.10% F.S. |
Pressure accuracy ambient temp. (0 to 50°C / 32 to 122°F) |
±25 mbar / 0.35 psi |
±0.15% F.S. |
| ±70, 350 mbar / 1, 5 psi |
±0.10% F.S. |
| All other pressure ranges |
±0.04% RDG + 0.01% F.S. |
| Vacuum |
±0.05% F.S. |
| Display |
LCD |
Graphical (with light) |
| Display resolution |
5 digits |
| Display update |
3 times per second |
| RS232 communication interface |
Connector |
LEMO |
| Serial |
0-5 VDC, 9600 baud, 8 data, no parity, 1 stop |
| Protocol |
ASCII command language |
Input / output (18 to 28°C / 65 to 82°F) |
mA range |
0 to 24 mA |
| mA accuracy |
±0.015% RDG + 2 μA |
| Transmitter supply |
24 VDC ±10% |
| Voltage measurement |
0 to 30 VDC |
| Voltage accuracy |
±0.015% RDG + 2mV |
| HART® resistor |
250 Ω |
| RTD range (ohms) |
84 to 140 Ω |
| RTD accuracy |
±0.015% RDG + 0.02 Ω |
| RTD range (temperature) |
-40 to 105ºC / -40 to 220ºF |
| RTC accuracy @ 0ºC/32ºF (temperature) |
±0.10ºC / 0.18ºF |
| Peak hold capture |
50 milliseconds |
| Switch test input |
5V (<1mA) |
| Media compatibility |
Nickel plated brass and 316 stainless steel |
| Environmental |
Operating temperature |
-10 to 50°C / 14 to 122°F |
| Storage temperature |
-20 to 60°C / -4 to 140°F |
| Ingress protection rating |
IP54 |
| Pressure connection |
All calibrators |
1/8” BSP female |
| Pressure overload |
Overload alarm |
“OL” in display at approx. +20% F.S. |
| Power supply |
Battery |
4 x 1.5 VDC Alkaline |
| Battery type |
AA, LR6, MN1500, AM3 |
| Battery lifetime |
Typically more than 35 hours |
| Low battery indicator |
Yes |
| Instrument dimensions (LxWxH) |
Calibrator |
201x99x50 mm / 8.3x3.9x2.0 in |
| HPC500 weight (incl. battery) |
665 g / 23.5 oz |
| Calibrator, shipping |
243x180x80 mm/ 9.6x7.1x3.1 in |
| Calibrator weight, shipping |
1.1 kg / 39.5 oz |
| Miscellaneous |
Compliance: EN 61326 : 2006 and CISPR 11, Edition 5.0 - 2009 Class “B” |
|
| |
Ametek HPC 500 System A• AXX/0 to 2 bar (0 to 30 psi)
• AHX/0 to 40 bar (0 to 580 psi) This system includes the HPC calibrator together with one pneumatic hand pump: T-960 and T-970, depending on the chosen pressure range. System A is an easy-to-use single hand operated calibration system. No need for a flat surface to operate the system - just hold it in your hand. |
Ametek HPC 500 System B• BXX/Vacuum to 2 bar (30 psi)
• BHX/Vacuum to 40 bar (580 psi) This system includes the dual function pneumatic hand pump. With this pump you can calibrate both vacuum and pressure applications. It takes just a few seconds to switch between vacuum and pressure, just push one button (valve) on the T-975 hand pump |
Ametek HPC 500 System C• CXX/0 to 200 bar (3,000 psi)
• CHX/0 to 350 bar (5,000 psi) This system consists of an HPC calibrator together with a hydraulic, high pressure hand pump T-620 or T-620H featuring an oil reservoir to prime the system. |
Ametek HPC 500 System D• DOX/0 to 350 bar (5,000 psi) oil
• DWX/0 to 350 bar (5,000 psi) water This system consists of an HPC calibrator with a hydraulic, high pressure screw pump. System D is an easy-touse calibration system. Place the pump on a flat surface and turn the handle to generate pressure. The calibrator may be adjusted to give the best viewing angle. The system includes a manifold for connection of the test device, a fine adjustment volume adjuster (optional), and a reservoir for extra oil or water (optional). |
Ametek HPC 500 System E• EXX/0 to 700 bar (10,000 psi) This system consists of an HPC calibrator together with a rugged, hydraulic, high pressure pump. |
Ametek HPC 500 System F• FOx/0 to 700 bar (10,000 psi) oil
• FWx/0 to 700 bar (10,000 psi) water) System F is an easy-to-use calibration system. The hydraulic pump makes it very easy to prime the system. The pump contains 1.23 l of liquid. |
| |
| Ordering Guide |
| Code |
Description |
|
|
|
|
|
|
|
|
| No calibrator, pressure system only |
|
| Code |
Pressure range |
| 25MD |
| 70MD |
| 350MD |
| 001A |
| 001C |
| 002A |
| 002C |
| 007A |
| 007C |
| 020A |
| 020C |
| 035C |
| 070G |
| 200G |
| 350G |
| 700G |
|
| ±25 mbar / 0.35 psi differential |
| ±70 mbar / 1 psi differential |
| ±350 mbar / 5 psi differential |
| 0 to 1.1 bar / 16 psi absolute |
| Vacuum to 1 bar / 15 psi gauge/compound |
| 0 to 2 bar / 30 psi absolute |
| Vacuum to 2 bar / 30 psi gauge/compound |
| 0 to 7 bar / 100 psi absolute |
| Vacuum to 7 bar / 100 psi gauge/compound |
| 0 to 20 bar / 290 psi absolute |
| Vacuum to 20 bar / 290 psi gauge/compound |
| Vacuum to 35 bar / 500 psi gauge/compound |
| 0 to 70 bar / 1,000 psi gauge |
| 0 to 200 bar / 2,900 psi gauge |
| 0 to 350 bar / 5,000 psi gauge |
| 0 to 700 bar / 10,000 psi gauge |
|
| Code |
Calibration Certificate |
|
|
| NIST traceable calibration certificate |
|
| Code |
Accessories Optional |
|
|
| Rechargeable battery pack |
| Soft Case |
| Interface Kit LEMO to RS232 |
| Temperature sensor Pt100 |
|
| Code |
Pressure System |
| IND |
| AXX | |
| AHX | |
| BXX | |
| BHX | |
| CXX | |
| CHX | |
| DOX | |
| DWX | |
| EXX | |
| FWB | |
| FWV | |
| FWE | |
| FOB | |
| FOV | |
| FOE | |
|
| Calibrator only |
| Syst. A, T-960 pump ranges up to 2 bar/30 psi |
| Syst. A, T-970 pump ranges up to 35 bar/500 psi |
| Syst. B, T-965 pump ranges up to 2 bar/30 psi |
| Syst. B, T-970 pump ranges up to 35 bar/500 psi |
| Syst. C, T-620 pump ranges up to 200 bar/2,900 psi OIL |
| Syst. C, T-620H pump ranges up to 350 bar/5,000 psi OIL |
| Syst. D, 65-P016 pump ranges up to 350 bar/5,000 psi OIL |
| Syst. D, 65-P017 pump ranges up to 350 bar/5,000 psi WATER |
| Syst. E, 65-P014 pump ranges up to 700 bar/10,000 psi OIL |
| Syst. F, T-1 pump ranges up to 700 bar/10,000 psi WATER/Buna-N |
| Syst. F, T-1 pump ranges up to 700 bar/10,000 psi WATER/VITON |
| Syst. F, T-1 pump ranges up to 700 bar/10,000 psi WATER/EPT |
| Syst. F, T-1 pump ranges up to 700 bar/10,000 psi OIL |
| Syst. F, T-1 pump ranges up to 700 bar/10,000 psi OIL/VITON |
| Syst. F, T.1 pump ranges up to 700 bar/10,000 psi OIL/EPT |
|
| Sample Order Number |
| HPC502035CGBCITBHX: HPC502, vacuum to 35 bar, NIST traceable certificate, rechargeable battery package, soft case, interface kit, temperature sensor, system B T-975 pump |
|
|
Ordering Information |
| Model |
Description |
Buy Online |
Price |
| HPC502 |
Ametek HPC502 Handheld Pressure
Calibrator |
Please Call |
| Included Accessories |
| |
- 1 HPC502 calibrator
- 1 Traceable calibration certificate (NIST) with pressure and vacuum performance
- 1 4 x 1.5 volt batteries
- 1 Adapter to 1/4” NPT male from 1/8” BSP male
- 1 Adapter 1/4” BSP female from 1/8” BSP male
- 1 1/8” sealed gasket / washer type
- 1 Test leads: red and black
- 1 Hand strap with clip
- 1 User manual
Additionally Included with System A delivery
- 1 Hand pump T-960 or T-970 with a 0.6 m / 24 in hose with 1/4” BSP and NPT female terminations
- 1 3/8” BSP female adapter with 1/4” BSP and NPT female terminations
- 1 Quick connector between pump and HPC calibrator
- 1 1 roll of Teflon tape
- 1 Protective carrying case
Additionally Included with System B delivery
- 1 Hand pump T-965 or T-975 with a 0.6 m / 24 in hose with 1/4” BSP and NPT female terminations
- 1 3/8” BSP female adapter with 1/4” BSP and NPT female terminations
- 1 Quick connector between pump and HPC calibrator
- 1 1 roll of Teflon tape
- 1 Protective carrying case
Additionally Included with System C delivery
- 1 Hand pump T-620 or T-620H with a 0.6 m / 24 in hose with 1/4” BSP and NPT female terminations
- 1 1 roll of Teflon tape
- 1 Protective carrying case
Additionally Included with System D delivery
- 1 Spindle pump for hydraulic oil or for water
- 1 10 x 1/4” bonded seals
- 1 Allen key 6 mm
- 1 2 x 1/4” NPT female adapters
- 1 1 roll of Teflon tape
- 1 Protective carrying case
Additionally Included with System E delivery
- 1 Hydraulic pump
- 1 10 x 1/4” bonded seals
- 1 Allen key 6 mm
- 1 2 x 1/4” NPT female adapters
- 1 1 roll of Teflon tape
- 1 Volume adjuster for fine adjustment
- 1 Protective carrying case
|
Included |
|