HOME > AMETEK > HANDHELD-PRESSURE-CALIBRATORS > HPC500 ametek logo
 

Ametek HPC500
Handheld Pressure Calibrator

  • Single sensor high accuracy pressure calibrator
  • mA measurement
  • Voltage measurement
  • 24 VDC transmitter supply
  • High speed pressure switch test
  • High speed min./max. hold
  • Temperature measurement with external RTD sensor
  • JOFRA APM pressure module connection
  • RS232 communication
  • On-line calculation of sensor error %
  • Automatic leak test timer function
  • Delta/sum calculation on pressure measurements
  • Display contrast adjustment
  • Instrument setup lock
  • Storage of 5 setups
  • Setup of automatic off timer
  • Setup of no. of display windows/measurement channels
  • Select display high or low resolution
  • Setup of backlight timer
  • HART resistor on/off
  • Normal or dampened display update rate

Click here for larger image - Ametek HPC500 Handheld Pressure CallibratorClick here for larger image - Ametek HPC500 Handheld Pressure Callibrator
Ametek HPC500 Shown

Product Information
Datasheet 230 KBpdf
Ordering Guide
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
pdfPDF Help
 
HPC500 Specifications
Pressure; gauge / compound ranges bar -0.96 to 1 and 2
-0.82 to 7, 20 and 35
psi -14 to 15 and 30
-12 to 100, 300 and 500
Pressure; gauge bar 70, 200, 350 and 700
psi 1,000. 3,000, 5,000 and 10,000
Pressure; absolute ranges bar 0.025 to 1.1 and 2
0.07 to 7 and 20
psi 0.35 to 16 and 30
1 to 100 and 300
Pressure; differential ranges mbar ±25, ±70 and ±350
psi. ±0.35, ±1 and ±5
Engineering units (built-in) User selectable 15 units
Pressure accuracy ambient temp.
(18 to 28°C / 65 to 82°F)
±25 mbar / 0.35 psi ±0.025% F.S.
±70, 350 mbar / 1, 5 psi ±0.05% F.S.
All other pressure ranges ±0.025% RDG + 0.01% F.S.
Vacuum ±0.10% F.S.
Pressure accuracy ambient temp.
(0 to 50°C / 32 to 122°F)
±25 mbar / 0.35 psi ±0.15% F.S.
±70, 350 mbar / 1, 5 psi ±0.10% F.S.
All other pressure ranges ±0.04% RDG + 0.01% F.S.
Vacuum ±0.05% F.S.
Display LCD Graphical (with light)
Display resolution 5 digits
Display update 3 times per second
RS232 communication interface Connector LEMO
Serial 0-5 VDC, 9600 baud, 8 data, no parity, 1 stop
Protocol ASCII command language
Input / output
(18 to 28°C / 65 to 82°F)
mA range 0 to 24 mA
mA accuracy ±0.015% RDG + 2 μA
Transmitter supply 24 VDC ±10%
Voltage measurement 0 to 30 VDC
Voltage accuracy ±0.015% RDG + 2mV
HART® resistor 250 Ω
RTD range (ohms) 84 to 140 Ω
RTD accuracy ±0.015% RDG + 0.02 Ω
RTD range (temperature) -40 to 105ºC / -40 to 220ºF
RTC accuracy @ 0ºC/32ºF (temperature) ±0.10ºC / 0.18ºF
Peak hold capture 50 milliseconds
Switch test input 5V (<1mA)
Media compatibility Nickel plated brass and 316 stainless steel
Environmental Operating temperature -10 to 50°C / 14 to 122°F
Storage temperature -20 to 60°C / -4 to 140°F
Ingress protection rating IP54
Pressure connection All calibrators 1/8” BSP female
Pressure overload Overload alarm “OL” in display at approx. +20% F.S.
Power supply Battery 4 x 1.5 VDC Alkaline
Battery type AA, LR6, MN1500, AM3
Battery lifetime Typically more than 35 hours
Low battery indicator Yes
Instrument dimensions (LxWxH) Calibrator 201x99x50 mm / 8.3x3.9x2.0 in
HPC500 weight (incl. battery) 635 g / 22.4 oz
Calibrator, shipping 243x180x80 mm/ 9.6x7.1x3.1 in
Calibrator weight, shipping 1.1 kg / 39.5 oz
Miscellaneous Compliance: EN 61326 : 2006 and CISPR 11, Edition 5.0 - 2009 Class “B”
 

Ametek HPC 500 System A

• AXX/0 to 2 bar (0 to 30 psi)   • AHX/0 to 40 bar (0 to 580 psi)
This system includes the HPC calibrator together with one pneumatic hand pump: T-960 and T-970, depending on the chosen pressure range. System A is an easy-to-use single hand operated calibration system. No need for a flat surface to operate the system - just hold it in your hand.

Ametek HPC 500 System B

• BXX/Vacuum to 2 bar (30 psi)   • BHX/Vacuum to 40 bar (580 psi)
This system includes the dual function pneumatic hand pump. With this pump you can calibrate both vacuum and pressure applications. It takes just a few seconds to switch between vacuum and pressure, just push one button (valve) on the T-975 hand pump

Ametek HPC 500 System C

• CXX/0 to 200 bar (3,000 psi)   • CHX/0 to 350 bar (5,000 psi)
This system consists of an HPC calibrator together with a hydraulic, high pressure hand pump T-620 or T-620H featuring an oil reservoir to prime the system.

Ametek HPC 500 System D

• DOX/0 to 350 bar (5,000 psi) oil   • DWX/0 to 350 bar (5,000 psi) water
This system consists of an HPC calibrator with a hydraulic, high pressure screw pump. System D is an easy-touse calibration system. Place the pump on a flat surface and turn the handle to generate pressure. The calibrator may be adjusted to give the best viewing angle. The system includes a manifold for connection of the test device, a fine adjustment volume adjuster (optional), and a reservoir for extra oil or water (optional).

Ametek HPC 500 System E

• EXX/0 to 700 bar (10,000 psi)
This system consists of an HPC calibrator together with a rugged, hydraulic, high pressure pump.

Ametek HPC 500 System F

• FOx/0 to 700 bar (10,000 psi) oil   • FWx/0 to 700 bar (10,000 psi) water)
System F is an easy-to-use calibration system. The hydraulic pump makes it very easy to prime the system. The pump contains 1.23 l of liquid.
 
Ordering Guide
Code Description
 HPC
Type
 500
Model
 None
No calibrator, pressure system only
Code Pressure range
 25MD
 70MD
 350MD
 001A
 001C
 002A
 002C
 007A
 007C
 020A
 020C
 035C
 070G
 200G
 350G
 700G
±25 mbar / 0.35 psi differential
±70 mbar / 1 psi differential
±350 mbar / 5 psi differential
0 to 1.1 bar / 16 psi absolute
Vacuum to 1 bar / 15 psi gauge/compound
0 to 2 bar / 30 psi absolute
Vacuum to 2 bar / 30 psi gauge/compound
0 to 7 bar / 100 psi absolute
Vacuum to 7 bar / 100 psi gauge/compound
0 to 20 bar / 290 psi absolute
Vacuum to 20 bar / 290 psi gauge/compound
Vacuum to 35 bar / 500 psi gauge/compound
0 to 70 bar / 1,000 psi gauge
0 to 200 bar / 2,900 psi gauge
0 to 350 bar / 5,000 psi gauge
0 to 700 bar / 10,000 psi gauge
Code Calibration Certificate
 G
NIST traceable calibration certificate
Code Accessories Optional
 B
 C
 I
 T
Rechargeable battery pack
Soft Case
Interface Kit LEMO to RS232
Temperature sensor Pt100
Code Pressure System
 IND
 AXX
 AHX
 BXX
 BHX
 CXX
 CHX
 DOX
 DWX
 EXX
 FWB
 FWV
 FWE
 FOB
 FOV
 FOE
Calibrator only
Syst. A, T-960 pump ranges up to 2 bar/30 psi
Syst. A, T-970 pump ranges up to 35 bar/500 psi
Syst. B, T-965 pump ranges up to 2 bar/30 psi
Syst. B, T-970 pump ranges up to 35 bar/500 psi
Syst. C, T-620 pump ranges up to 200 bar/2,900 psi OIL
Syst. C, T-620H pump ranges up to 350 bar/5,000 psi OIL
Syst. D, 65-P016 pump ranges up to 350 bar/5,000 psi OIL
Syst. D, 65-P017 pump ranges up to 350 bar/5,000 psi WATER
Syst. E, 65-P014 pump ranges up to 700 bar/10,000 psi OIL
Syst. F, T-1 pump ranges up to 700 bar/10,000 psi WATER/Buna-N
Syst. F, T-1 pump ranges up to 700 bar/10,000 psi WATER/VITON
Syst. F, T-1 pump ranges up to 700 bar/10,000 psi WATER/EPT
Syst. F, T-1 pump ranges up to 700 bar/10,000 psi OIL
Syst. F, T-1 pump ranges up to 700 bar/10,000 psi OIL/VITON
Syst. F, T.1 pump ranges up to 700 bar/10,000 psi OIL/EPT
Sample Order Number
HPC500035CGBCITBHX: HPC500, vacuum to 35 bar, NIST traceable certificate, rechargeable battery package, soft case, interface kit, temperature sensor, system B T-975 pump
Ordering Information
Model Description Buy Online Price
HPC500 Ametek HPC500 Handheld Pressure Calibrator Please Call
Included Accessories
 
  • 1 HPC500 calibrator
  • 1 Traceable calibration certificate (NIST) with pressure and vacuum performance
  • 1 4 x 1.5 volt batteries
  • 1 Adapter to 1/4” NPT male from 1/8” BSP male
  • 1 Adapter 1/4” BSP female from 1/8” BSP male
  • 1 1/8” sealed gasket / washer type
  • 1 Test leads: red and black
  • 1 Hand strap with clip
  • 1 User manual

Additionally Included with System A delivery

  • 1 Hand pump T-960 or T-970 with a 0.6 m / 24 in hose with 1/4” BSP and NPT female terminations
  • 1 3/8” BSP female adapter with 1/4” BSP and NPT female terminations
  • 1 Quick connector between pump and HPC calibrator
  • 1 1 roll of Teflon tape
  • 1 Protective carrying case

Additionally Included with System B delivery

  • 1 Hand pump T-965 or T-975 with a 0.6 m / 24 in hose with 1/4” BSP and NPT female terminations
  • 1 3/8” BSP female adapter with 1/4” BSP and NPT female terminations
  • 1 Quick connector between pump and HPC calibrator
  • 1 1 roll of Teflon tape
  • 1 Protective carrying case

Additionally Included with System C delivery

  • 1 Hand pump T-620 or T-620H with a 0.6 m / 24 in hose with 1/4” BSP and NPT female terminations
  • 1 1 roll of Teflon tape
  • 1 Protective carrying case

Additionally Included with System D delivery

  • 1 Spindle pump for hydraulic oil or for water
  • 1 10 x 1/4” bonded seals
  • 1 Allen key 6 mm
  • 1 2 x 1/4” NPT female adapters
  • 1 1 roll of Teflon tape
  • 1 Protective carrying case

Additionally Included with System E delivery

  • 1 Hydraulic pump
  • 1 10 x 1/4” bonded seals
  • 1 Allen key 6 mm
  • 1 2 x 1/4” NPT female adapters
  • 1 1 roll of Teflon tape
  • 1 Volume adjuster for fine adjustment
  • 1 Protective carrying case
Included