Agilent N2862A
Passive Probe, 10:1, 150 MHz, 1.2m

  • Cable length 1.2 m
  • Bandwidth DC to 150 MHz
  • Risetime 2.33 ns
  • Attenuation ratio 10:1
  • Input resistance 10 MΩ (when terminated into 1 MΩ)
  • Input capacitance ≈12 pF
  • Maximum input 300 V RMS

Click here for larger image of the Agilent N2862-A Oscillioscope Probe!Click here for larger image!
Agilent N2862A Shown

Product Information
Datasheet 211 KB
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information
PDF Help
  
The Agilent N2862A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.