ACR SmartReader Plus 5
Three-Channel Temperature (Thermocouple) Datalogger

  • Three Channels
  • Monitor extremely high temperatures
  • Monitor temperature over a wide range
  • Use with a variety of different thermocouple probes
  • Greater Resolution and accuracy than the SmartReader5
  • Requires the TrendReader Standard 2 (Runs on Windows 2000 and Windows XP)

Click here for a larger image of the ACR Systems SmartReader Plus 5!Click for larger image
ACR SmartReaderPlus 5 Shown

Product Information

Datasheet 74 KB
Memory Size
Calculator
HTML

PDF Help

 
The SmartReader Plus 5 data logger is ideal for those applications that require monitoring extremely high temperatures or monitoring temperature over a wide range. The logger has one internal channel for measuring ambient temperature and two external channels for use with ACR thermocouple wire or any J, K, S, T or E type thermocouple wire.
 
SmartReaderPlus 5 Specifications
No. of Channels
Three  
  • One for Ambient Temperature (also cold-junction compensation)
  • Two for thermocouple temperature
Thermocouple Specs:
Range and Resolution:
J type: -50 to 600ºC (-55 to 1100ºF); 0.30ºC (0.55ºF)
K type: -100 to 1150ºC (-145 to 2100ºF); 0.50ºC (0.90ºF)
S type: 0 to 1450ºC (32 to 2642ºF ); 1.0ºC (1.8ºF)
T type: -200 to 400ºC (-325 to 750ºF); 0.40ºC (0.75ºF)
E type: -50 to 680ºC (-58 to 1250ºF); 0.24ºC (0.44ºF)
Clock Accuracy: +/- 2 seconds per day
Memory Size: SRP-005 32 KB (21,500 readings)
SRP-005-128K 128 KB (87,000 readings)
Sampling Methods:
  1. Continuous (First-in, First-out)
  2. Stop when full (Fill then stop)
Sampling Rates: User selectable rates from .04 seconds to 8 hours
Resolution: 12-bit
External Connector: Removable Screw-Type Terminal Strip with Common (-) Connection
General Specifications Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Case Material Noryl plastic
Mounting Magnetic backing or  locking eyelet
Power Source Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 Years under normal use
Internal Temperature Sensor Type NTC thermistor (10,000 ohms @ 25°C [77°F])
Range -40 to 70°C (-40 to 158°F)
Accuracy +/- 0.2ºC over the range: 0 to 70ºC (+/- 0.3ºF over the range: 32 to 158ºF)
Resolution 0.03°C (0.05°F) at 25°C (77°F). Better than 0.07°C
(0.12°F) between -25°C (-13°F) and 70°C (158°F).
Better than 0.13°C (0.23°F) between -40°C (-40°F)
and -25°C (-13°F)
 
PC Requirements
Processor/Operating System IBM PC or 100% compatible running Windows 3.1, '95, '98, 2000, ME, NET, XP
Available Hard drive space At Least 2MB
Memory At Least 2MB
Communication Ports 1 Free Serial Port
Software
Basic Software: TrendReader 2 System Requirements (Required for Standard use)
Processor Pentium II-350MHz or Faster
Operating System Windows 2000 SP4, XP SP2
Available Hard drive space At Least 250 MB of Hard disk space
Memory 128 mb of Ram (256 MB Recommended)
Communication Ports USB or Serial Port, dependant on interface cable
Internet Browser Internet Explorer 6 or higher
Screen resolution 1024 x 768 or higher
Additional Equipment Mouse or other pointing device
More info More info on the TrendReader Standard 2>>
 
Ordering Information
ACR TrendReader 2 Software required for usage
ModelDescriptionBuy Online Price
SRP-005
MFR ID: 01-0012
 
ACR Systems SRP-005 SmartReader Plus 5 - 32 KB Three channel, 12 bit 32 KB data logger (One ambient temperature and two external thermocouple channels). (Catalog# 01-0012)  Buy Now$510.00
SRP-005-128K
MFR ID: 01-0121
 
ACR Systems SRP-005-128K SmartReader Plus 5 - 128 KB Three channel, 12 bit, 128 KB data logger (One ambient temperature and two external thermocouple channels). (Catalog# 01-0121)  Buy Now$819.00
Software
TRS2-FULL INSTALL
MFR ID: 01-0228
ACR Systems TRS2-FULL INSTALL TrendReader 2 Full Install CD. (Latest version) Buy Now $109.00
TRS2UPGRADE  ACR Systems TRS2-UPGRADE TrendReader 2 Upgrade CD. (Requires a previous version of TrendReader Standard.) Discontinued
TRS2WIC101  ACR Systems TRS2-W/IC-101 TrendReader 2 Interface Package (IC-101) Software CD & Serial Port Interface cable for SR/SRP data loggers Discontinued
TRS2-W/IC-102
MFR ID: 01-0226
ACR Systems TRS2-W/IC-102 TrendReader 2 Interface Package (IC-102) Software CD & USB Interface cable for SR & SRP data loggers Buy Now $189.00
Included Accessories
 
  • 1 - Users guide
Included
Optional Accessories
TCJ
MFR ID: 31-0014 
Range -50°C to 600°C (-55°F to 1100°F) Buy Now $6.00
ACR Systems TCJ  Bulk Wire 20 gauge J type thermocouple wire with duplex insulated Teflon jacke
TCJ-WELDED
MFR ID: 01-0102 
Range -50°C to 600°C (-55°F to 1100°F) Buy Now $13.00
ACR Systems TCJ-WELDED J Type Thermocouple Wire - Welded tip, 20 gauge J type thermocouple wire with duplex insulated Teflon jacket.
TCK
MFR ID: 31-0015 
Range -100°C to 1150°C (-145°F to 2100°F) Buy Now $6.00
ACR Systems TCK 20 gauge K type thermocouple wire (bulk) with duplex insulated Teflon jacket
TCK-WELDED
MFR ID: 01-0103 
Range -100°C to 1150°C (-145°F to 2100°F) Buy Now $13.00
ACR Systems TCK-WELDED Welded tip, 20 gauge K type thermocouple wire with duplex insulated Teflon jackete.
TCT
MFR ID: 31-0016 
Range -200°C to 400°C (-325°F to 750°F) Buy Now $6.00
ACR Systems TCT 20 gauge T type thermocouple wire (bulk) with duplex insulated PVC jacket
TCT-WELDED
MFR ID: 01-0104 
Range -200°C to 400°C (-325°F to 750°F) Buy Now $13.00
ACR Systems TCT-WELDED Welded tip, 20 gauge T type thermocouple wire with duplex insulated PVC jacket.
TC-WELD
MFR ID: 89-0003 
Range -200°C to 400°C (-325°F to 750°F) Buy Now $27.00
ACR Systems TC-WELD Thermocouple Tip Welding Service One end welded. Customer must supply or order thermocouple cable separately.
Alarms
AM-100-120
MFR ID: 01-0167
ACR Systems AM-100-120 NA Alarm module, stereo Y-adapter, 1' male-male stereo cable, and 120 V NA power supply for SmartReader Plus Buy Now $345.00
AM-100-240
MFR ID: 01-0168
ACR Systems AM-100-240 EU Alarm module, stereo Y-adapter, 1' male-male stereo cable, and 240 V Cont. power supply for SmartReader Plus Buy Now $345.00
PC Interface Cable
IC101  ACR Systems IC-101  9-pin PC serial port to logger interface cable. Compatible with SmartReader & SmartReader Plus loggers Discontinued
IC-102
MFR ID: 01-0088
 
ACR Systems IC-102 USB port to logger interface cable. Compatible with SmartReader &  SmartReader Plus loggers Buy Now $99.00
CB-020
MFR ID: 31-0024
 
ACR Systems CB-020 25' 20' stereo cable extension for an IC-101 cable, 8 port network interface cable, or SmartReader Plus stereo style network Buy Now $26.00
SC-004
MFR ID: 31-0009
ACR Systems SC-004 Replacement 6' cable for old-style IC-101 cables with removable stereo cables. Male to male connection Buy Now $6.50
USB100ACR ACR Systems USB-100 USB-Serial Port Cable Converts a USB port to a 9 pin serial port Discontinued
Networking
USMC  ACR Systems USM-C Logger/Network Modem (Computer Station) Pre-programmed, external PC Telco modem for communicating remotely with single or networked loggers. North American version Discontinued
USMR  ACR Systems USM-R Logger/Network Modem (Remote Station) Pre-programmed, external remote Telco modem for communicating remotely with single or networked loggers. North American version Discontinued
MA100 ACR Systems MA-100 Modem-Logger Int. Cable Adapter (MA-100) Adapts the IC-101/LIC-101 logger interface cable for use with analog Telco modems Discontinued
31-0025 ACR Systems 31-0025 Network Y Splitter - Stereo N/C (YA-202) Buy Now $13.00
01-0098 ACR Systems YA-200 Network Y Splitter - Stereo W/C (YA-200) Allows a SmartReader Plus logger to be added to an ACR-stereo type network. Includes 1' male to male adapter cable. Buy Now $19.00
YA-201
MFR ID: 01-0166
ACR Systems YA-201 Network Y Splitter-Telco (YA-201) Allows a SmartReader Plus logger to be added to an ACR-Telco type network Discontinued
YADAPTER
MFR ID: 31-0018
ACR Systems YADAPTER Network Y Splitter - Stereo N/C (YA-200) Allows a SmartReader Plus logger to be added to an ACR-stereo type network. No 1' male to male adapter cable included Discontinued
31-0044 ACR 31-0044 Telco/Logger Network Cable 26 AWG 4-Conductor, 1ft (0.3m)  Buy Now $0.60
01-0079 ACR 010079 RFA Adaptor for SmartReader Plus. DE9M Connector w/bult in Null Modem for connection toDEC (RF/Cellular Modem)  Buy Now $124.00
390006 ACR 39-0006 Moxa NPort Express DE-311/110V. Enables SmartReader Plus to communicate over a LAN or Ethernet Discontinued
39-0008 ACR 39-0008 Moxa NPort W2150 Plus. Enables SmartReader Plus to communicate over a LAN or Ethernet Wirelessly  Buy Now $450.00
Power Supplies
BP-101
MFR ID: 01-0078
ACR Systems BP-101 Portable power supply for SmartReader Plus data loggers for sampling faster than 8 seconds. Buy Now $56.00
PS-201-NA
MFR ID: 01-0165
ACR Systems PS-201-NA 120V N/A 120V AC to 5V DC power supply for SmartReader Plus networks with min. of 3 loggers or 50' of network cable Buy Now $69.00
33-0014 ACR 33-0014 Power Supply 12V with Australia Plug  Buy Now $72.00
33-0015 ACR 33-0015 Power Supply 12V with N. America Plug  Buy Now $59.00
33-0016 ACR 33-0016 Power Supply 12V with Shuko Plug  Buy Now $59.00
33-0017 ACR 33-0017 Power Supply 12V with U.K. Plug  Buy Now $59.00
33-0019 ACR 33-0019 Power Supply 12V with 4 Plug Kit  Buy Now $59.00
Cases
GLS ACR Systems GLS Logger Protective Sock Protective Gortex® sock for protecting loggers from debris and contaminants. Ideal for relative humidity loggers and probes Discontinued
WB-100
MFR ID: 01-0057
Size: 127 x 127 x 76mm . Buy Now $110.00
ACR Systems WB-100 NEMA 4X clear-faced weatherproof box for all ACR loggers
WBC100 ACR Systems WBC-100 Weatherproof Box Self-Sealing Connectors Additional self-sealing connectors for the Weatherproof Logger Box. (Catalog# 21-0003) Discontinued
Software
SDKSRPNAUTILUS  ACR Systems SDK-SRP/NAUTILUS SDK for SRP and Nautilus: Software on CD, Data Logger and Interface Cable, 90-day Technical Support. Discontinued
Other Accessories
18-0010  ACR Systems 9-25-ADP 25-9 Pin Serial Port Adapter Converts 25 pin male serial port to a 9 pin male port Discontinued
RS-232-EXT
MFR ID: 31-0017
 
ACR Systems RS-232-EXT 9-Pin Serial Port Extension Cable (RoHS) Buy Now $19.00
SRP-DM
MFR ID: 01-0171
 
ACR Systems SRP-DM Portable Real-time Display Module for any SmartReader Plus Data Logger Buy Now Sale $521.81
(Reg. $545.00)
SR-CAP
MFR ID: 21-0029
 
ACR Systems SR-CAP Protective Cap Plastic for the SmartReader/SmartReader Plus communication port from debris and contaminants Discontinued
TB-11
MFR ID: 29-0004
 
ACR Systems TB-11 Terminal Block - 11 Pin (RoHS) 11-pin female terminal block for SmartReader/SmartReader Plus sensor inputs. Buy Now $15.00
STR-11
MFR ID: 29-0013
 
ACR Systems STR-11 Terminal Block Strain Relief (RoHS) Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks. Buy Now $16.00
00-0060 ACR 00-0060 Terminal Block Screwdriver. Flat screwdriver for tightening terminal block on SmartReader/SmartReaderPlus  Buy Now $3.00