ACR SmartReader Plus 3
Eight Channel AC Current and Voltage Data Logger

  • Eight Channel
  • Monitor AC current and voltage (single or 3-phase)
  • Determine energy consumption
  • 10-year battery life
  • Memory Capacity of up to 1,048,000 readings
  • Remote access via modem or Ethernet
  • Network capable
  • Alarm Dial out
  • User configurable

Click here for a larger image of the ACR Systems SmartReaderPlus3!Click for larger image
ACR SmartReaderPlus 3 Shown

Product Information

Datasheet 83 KB
Ordering Info

Jump to Product Models, Prices, Accessories, and Ordering Information

PDF Help

 
The SmartReader Plus 3 easily and accurately records AC current and voltage. Simply connect the logger to ACR's current probes (which are clamped around the power leads) and voltage transducer and begin recording. From this data, you can also determine energy consumption (kWh) with TrendReader® Standard software.
 
SmartReaderPlus 3 Specifications
No. of Channels
Eight  
  • One for Ambient Temperature
  • Four for AC current (with ACR current probes)
  • Three for AC Voltage (with ACR voltage transducers, single phase or 3-phase)
Clock Accuracy +/- 2 seconds per day
Resolution 12-bit
Memory Size
32 KB (21,500 readings)
128 KB (87,000 readings)
1.5 MB (1,048,000 readings)
Sampling Methods 1. Continuous (First-in, First-out)
2. Stop when full (Fill then stop)
Rates User selectable rates from 25 per second to once every 8 hours
Power Source Battery 3.6 volt Lithium, 1 Amp-Hour
Power Consumptions 5 to 10 microamps (continuous)
Battery Life 10 Years under normal use
General Specifications Size 107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9")
Case Material Noryl plastic
Mounting Magnetic backing and locking eyelet
Certification Certified to CE standard EN50082-1: 1992 (European Generic Immunity) covering ESD, RFI, and EFT/B
Meets CE Standards EN55011 Class B: 1991 (European Radiated Emissions) and CISPR Class B: 1991 (International Radiated Emissions)

External Connector

Removable screw-type terminal strip with common (-) connection
 
Internal Temperature Sensor
Type Negative Temperature Coefficient Thermistor
Accuracy +/-0.2°C over the range of 0 to 70°C (+/-0.3°F over the range of 32 to 158°F
Range -40 to 70°C (-40 to 158°F)
Resolution 0.4°C (0.7°F) at 25°C (77°F); better than 1 °C (1.8°F) between -25°C and 70°C (-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C (-40°F and -13°F)
PC Requirements
Processor/Operating System IBM PC or 100% compatible running WIndows 3.1, '95, '98, 2000, ME, NET, XP
Available Hard drive space At Least 2MB
Memory At Least 2MB
Communication Ports 1 Free Serial Port
Software
Basic Software: TrendReader 2 System Requirements (Required for Standard use)
Processor Pentium II-350MHz or Faster
Operating System Windows 2000 SP4, XP SP2
Available Hard drive space At Least 250 MB of Hard disk space
Memory 128 mb of Ram (256 MB Recommended)
Communication Ports USB or Serial Port, dependant on interface cable
Internet Browser Internet Explorer 6 or higher
Screen resolution 1024 x 768 or higher
Additional Equipment Mouse or other pointing device
More info More info on the TrendReader Standard 2>>
 
Ordering Information
ACR TrendReader 2 Software required for usage
Model Description Buy Online Price
SRP003  ACR Systems SRP-003 SmartReader Plus 3 - 32 KB Eight channel, 12 bit, 32 KB data logger (One ambient temperature, four AC current and three 0-5V DC channels). (Catalog# 01-0010)  Buy Now $910.00
SRP003128K  ACR Systems SRP-003-128K SmartReader Plus 3 - 128 KB Eight channel, 12 bit, 128 KB data logger (One ambient temperature, four AC current and three 0-5V DC channels). (Catalog# 01-0114)  Buy Now $1,060.00
SRP00315M  ACR Systems SRP-003-1.5M SmartReader Plus 3 - 1.5 MB Eight channel, 12 bit, 1.5 MB data logger (One ambient temperature, four AC current and three 0-5V DC channels). (Catalog# 01-0143)  Buy Now $1,625.00
Software
TRS2FULLINSTALL  ACR Systems TRS2-FULL INSTALL TrendReader 2 Full Install CD. (Latest version) Buy Now $130.00
TRS2UPGRADE  ACR Systems TRS2-UPGRADE TrendReader 2 Upgrade CD. (Requires a previous version of TrendReader Standard.) Buy Now $110.00
TRS2WIC101  ACR Systems TRS2-W/IC-101 TrendReader 2 Interface Package (IC-101) Software CD & Serial Port Interface cable for SR/SRP data loggers Buy Now $230.00
TRS2WIC102  ACR Systems TRS2-W/IC-102 TrendReader 2 Interface Package (IC-102) Software CD & USB Interface cable for SR & SRP data loggers Buy Now $240.00
Included Accessories
 
  • 1 - Users guide
Included
Optional Accessories
AC Clamp-on Current Probes
Model Details Buy Online Price
A60FL Frequency 60Hz

Current

5, 25, 100, 250 Amps Buy Now $119.95
0-250A 60Hz AC current clamp-on probe
A65FL Frequency 50Hz

Current

5, 25, 100, 250 Amps Buy Now $143.00
0-250A 50Hz AC current clamp-on probe
A70FL Frequency 60Hz

Current

10, 50, 250, 500 Amps Buy Now $119.95
0-500A 60Hz AC current clamp-on probe
A75FL Frequency 50Hz

Current

10, 50, 250, 500 Amps Buy Now $150.00
0-500A 50Hz AC current clamp-on probe
AC Clamp-on Voltage Probes
VT1P Frequency 60Hz

Voltage

0 to 150V (Single Phase) Buy Now $331.00
120 VAC, 60Hz Single Phase voltage Transducer. For loggers with a 0-5 Volt channel
VT3P Frequency 60Hz

Voltage

0 to 600V (Three Phase) Buy Now $1,127.00
480 VAC, 60Hz Single Phase voltage Transducer. For loggers with a 0-5 Volt channel
Line Splitters
A47CL ACR Systems A-47CL N/A AC Current Line Splitter/Multiplier North American line splitter. Separates hot/neutral lines between electrical device and receptacle. Includes a 10X multiplier. For use with A60FL and A70FL Buy Now $54.00
A47L ACR Systems A-47L CEU AC Current Line Splitter/Multiplier Cont. Europe line splitter. Separates hot/neutral lines between electrical device and receptacle. Includes a 10X multiplier. For use with A65FL and A75FL Buy Now $42.00
Terminal Blocks
TB11 ACR Systems TB-11 Terminal Block - 11 Pin (RoHS) 11-pin female terminal block for SmartReader/SmartReader Plus sensor inputs. Buy Now $14.00
STR11 ACR Systems STR-11 Terminal Block Strain Relief (RoHS) Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks. Buy Now $15.00
Cables
IC101 ACR Systems IC-101 Logger-PC Interface Cable (IC-101) 9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers Buy Now $119.00
IC102 ACR Systems IC-102 Logger-PC Interface Cable (IC-102) USB port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers Buy Now $143.00
CB020 ACR Systems CB-020 Stereo Cable Extension Cable - 25' 20' stereo cable extension for an IC-101 cable, 8 port network interface cable, or SmartReader Plus stereo style network Buy Now $10.00
SC004 ACR Systems SC-004 Replacement 6' cable for old-style IC-101 cables with removable stereo cables. Male to male connection Buy Now $6.00
Networking
USMC ACR Systems USM-C Logger/Network Modem (Computer Station) Pre-programmed, external PC Telco modem for communicating remotely with single or networked loggers. North American version Buy Now $340.00
USMR ACR Systems USM-R Logger/Network Modem (Remote Station) Pre-programmed, external remote Telco modem for communicating remotely with single or networked loggers. North American version Buy Now $340.00
YA200 ACR Systems YA-200 Network Y Splitter - Stereo W/C (YA-200) Allows a SmartReader Plus logger to be added to an ACR-stereo type network. Includes 1' male to male adapter cable. Buy Now $25.00
YA201 ACR Systems YA-201 Network Y Splitter-Telco (YA-201) Allows a SmartReader Plus logger to be added to an ACR-Telco type network Buy Now $24.00
YADAPTER ACR Systems YADAPTER Network Y Splitter - Stereo N/C (YA-200) Allows a SmartReader Plus logger to be added to an ACR-stereo type network. No 1' male to male adapter cable included Buy Now $18.00
Power sources
BP101 ACR Systems BP-101 Fast Sampling Battery Pack - 101 Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds Buy Now $54.00
PS201NA ACR Systems PS-201-NA Net/Fast Sample Power Supply - 120V N/A 120V AC to 5V DC power supply for use with SmartReader Plus networks with minimum of three loggers or 50' of network cable Buy Now $66.00
Cases & Protectors
GLS ACR Systems GLS Logger Protective Sock Protective Gortex® sock for protecting loggers from debris and contaminants. Ideal for relative humidity loggers and probes Buy Now $35.00
SC100 ACR Systems SC-100 General Purpose Briefcase style, locking, customizable logger & accessory storage case Buy Now $155.00
Software
SDKSRPNAUTILUS  ACR Systems SDK-SRP/NAUTILUS SDK for SRP and Nautilus: Software on CD, Data Logger and Interface Cable, 90-day Technical Support. Buy Now $500.00
TBSWIN  ACR Systems TBS-WIN - Full install version of the latest version of TalkBack Alarm management software (3.5" disk). Buy Now $150.00
 

ACR Catalog   |   ACR Price List

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved