HOME > Aaronia > Accessories > emc-probe |
Aaronia PBS1 & PBS2
EMC EMI 100kHz to 3GHz Probe Sniffer Set
|
| |
- Perfect for locating interference sources
- Verification of official EMC limits
- Frequency range: 100kHz-3GHz
- Pre-Amplifier noise (PBS2): 3.5dB typical
- PreAmplifier type/gain (PBS2): "linear" falloff. 1MHz: 40dB; 500MHz: 37.5dB; 1GHz: 35dB
- Dimensions of case (L/W/D): (320x250x100) mm
|

Aaronia PBS2
Shown |
|
|
|
|
Aaronia's EMC probe set allows for straightforward pinpointing and measurement
of interference sources in electronic component groups as well as execution and
monitoring of generic EMC measurement. The EMI probe set is especially suitable for:
- Pinpointing interference sources
- Estimation of interference field strength
- Verification of shielding and filtering measures
- Identifying faulty components
- Detecting circuitry overly sensitive to interference
The set includes a total of 5 probes: 3 probes for magnetic field measurement and two
for measurement of electric fields. All probes are covered with an insulating layer, thus
allowing safe measurement of oscillators or mains lines.
The PBS2 probe set additionally contains a high-performance pre-amplifier, allowing
measurement of significantly weaker interference sources, boosting the sensitivity of our
instruments by up to 40dB.
All probes have deliberately been implemented as passive devices to make them usable as
transmitting devices as well. Consequently, components and circuits sensitive to interference
can easily be pinpointed.
|
|
| |
| Specifications |
| Size/Type |
Images |
Details |
dB/Frequency
Graphs |
Included in: |
| PBS1 |
PBS2 |
Isotropic
E-field sniffer |
 |
- H field shielding: 30dB
- Max. resonance frequency: >3GHz
- Connector: 50 Ohms BNC socket (f)
|
 |
 |
 |
Directional
E-field Probe |
 |
- E-field shielding: 30dB
- Max. resonance frequency: >3GHz
- Connector: 50 Ohms BNC socket (f)
|
 |
 |
 |
| Magnetic Field Probes |
| 10mm |
 |
- E Field shielding: 41dB
- Max. resonance frequency: 790MHz
- Connector: 50 Ohms BNC socket (f)
|
 |
 |
 |
| 30mm |
 |
- E Field shielding: 29dB
- Max. resonance frequency: 790MHz
- Connector: 50 Ohms BNC socket (f)
|
 |
 |
 |
| 60mm |
 |
- E Field shielding: 29dB
- Max. resonance frequency: 2.3GHzz
- Connector: 50 Ohms BNC socket (f)
|
 |
 |
 |
| 60mm |
 |
- high-performance pre-amplifier
- allows measurement of significantly weaker
interference sources
- boosts sensitivity of instruments by up to 40dB
|
|
 |
|
| |