Specifications |
|
Electrical |
|
Channels |
Two |
|
Connections |
Current Channel |
Voltage Channel |
|
Input Connection |
BNC |
Two
recessed banana jacks |
|
Input Range |
0 to 1Vac |
0 to 600VAC |
|
Resolution |
0.1mA |
0.1V |
|
Accuracy (50 or 60Hz) |
0 to
10mV unspecified |
0 to
5V unspecified |
| 10
to 50mV: ± (0.5% of Reading + 1mV) |
5 to
50V: ± (0.5% of Reading + 1V ) |
| 50
to 1000mV: ±(0.5% of Reading + 0.5mV) |
50
to 600V: ±(0.5% of Reading + 0.5V) |
|
Sample Rate |
64 samples/cycle |
|
Storage Rate |
Programmable from 125mS to 1 day |
|
Storage Technique |
Stop when full, FIFO and Extended
Recording Mode (XRM™) |
|
Recording Length |
15 minutes to 8 weeks, programmable
using DataView® |
|
Memory |
240,000 measurement (512KB). |
|
The recorded data is stored in
non-volatile memory & retained even if the battery is low or
removed. |
|
Communication |
USB 2.0 optically isolated |
|
Power Source |
2 x 1.5V AA-cell Alkaline batteries |
|
Battery Life |
100 hours to > 45 days
(dependent on storage rate/recording length) |
|
Mechanical |
|
Dimensions |
5.38 x 2.75 x 1.28" (136 x 70 x
32mm) |
|
Max Conductor Size |
Current probe dependent |
|
Weight (with battery) |
6.4 oz (181 grams) |
|
Case |
UL94-VO |
|
Vibration |
IEC 68-2-6 (1.5mm, 10 to 55Hz) |
|
Shock |
IEC 68-2-27 (30G) |
|
Drop |
IEC 68-2-32 (1m) |
|
Environmental |
|
Operating Temperature |
14° to 122°F (-10° to 50°C) |
|
Storage Temperature |
-4° to 140°F (-20° to 60°C) |