<< AEMC Simple Loggers
|
AEMC L101 TRMS Single Channel Current Data Logger
|
- Compatible standard current probes with voltage output and BNC connection
- 64 samples per cycle
- Programmable storage rates from 8 every second to 1 every day
- 3 user selectable storage modes
- Stores up to 240,000 measurements in non-volatile memory
- Powered by standard Alkaline batteries
- Lightweight, compact, fits anywhere
- 5 LED indicators quickly and clearly display Logger status
- Includes DataView® software for data storage, real-time waveform display, analysis and report generation
- Isolated USB communication
- 50V Cat III
|

AEMC L101 Shown
|
|
|
| |
The Simple Logger® II Model L101 is a one channel recording device powered
by an alkaline battery pack. Line tracking is performed such that 64
samples over one line cycle are taken. Frequency tracking is performed
over the range of ±2Hz around the nominal line frequency (50 or 60Hz).
Harmonic measurements are calculated from these 64 samples (Harmonics
are only available from the Simple Logger® II Control Panel within the
DataView® software).
The Simple Logger® II records TRMS at a rate of up to eight times per
second. The measurement process is performed no more than eight times
per second. TRMS calculations are performed on a single line cycle. This
means that the input(s) are ignored between measurement intervals.
The main advantage of the logger is its ability to perform a variety of
recording tasks with easy and intuitive setup from a computer using
DataView® software.
Analog information on the input is sampled and converted to a digital
signal. This digital signal is processed and stored along with scale and
time information. An optically isolated Universal Serial Bus (USB) port
provides for the transfer of data from the instrument’s internal memory
to the computer for analysis.. |
| |
| AEMC L101 Specification |
| Electrical |
| Channels |
One |
| Input Connection |
BNC |
| Measurement Range |
0 to 1V probe dependent |
| Resolution |
0.1mV |
| Accuracy |
0 to 10mV: Unspecified 10 to 50V: ±(0.5% of Reading + 1.0V) 50 to 1000V: ±(0.5% of Reading + 0.5V) |
| Sample Rate |
64 samples/Cycle |
| Storage Modes |
Programmable from 125ms to 1 day |
| Record Length |
15 minutes to 8 weeks, programmable using DataView |
| Memory |
240,000 measurements (512KB) - The Recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. |
| Communication |
USB 2.0 Optically Isolated |
| Power Source |
2 x 1.5V AA-cell alkaline batteries |
| Battery Life |
100 hours to >45 days (dependent on sample rate and recording length) |
| Mechanical |
| Dimensions |
5.38 x 2.75 x 1.28" (136 x 70 x 32mm) |
| Max Conductor Size |
Current Probe Dependent |
| Weight (with battery) |
6.4 oz (181 grams) |
| Case |
UL94-VO |
| Vibration |
IEC 68-2-6 (1.5mm, 10 to 55Hz) |
| Shock |
IEC 68-2-27 (30G) |
| Drop |
IEC 68-2-32 (1m) |
|
| |